Accepted answer
To be exact about it, the arithmetic only stops being confusing once you work it through once and see that it is straightforward.
Dead space quantified: a fixed-needle insulin syringe holds roughly 3 to 5 µL in the hub and needle after the plunger bottoms out. A luer-lock syringe with a detachable needle holds 35 to 100 µL depending on the hub design. At 5 mg/mL that is 15 to 25 µg lost per draw on the insulin syringe and 175 to 500 µg on the luer-lock — which over ten draws is the difference between losing a rounding error and losing half a milligram.
Worth being precise here: air bubbles at these volumes are a measurement problem rather than a safety one. A 2 mm bubble in a 0.3 mL syringe is roughly 4 µL, which at 10 units drawn is a four per cent error.
Published data on syringe dead space quantifies low-dead-space designs as retaining under 2 µL against 35 µL or more for conventional detachable-needle syringes.
I would flag the obvious failure mode: people get the concentration right, get the volume right, and then read the syringe against the wrong scale.
Do the arithmetic twice, ideally with someone else doing it independently.
4For what it is worth, my own result was within half a per cent of this. – gel_pack_warm 9 months ago 5Any reason this would differ for a longer peptide? – triple_agonist_q 16 days ago add a comment