Gradient slope is the most powerful parameter and almost nobody mentions it, which is why two reports on the same material disagree by a point.
Retention time is sequence-specific and method-specific, so comparing your result to a supplier value using a different method is meaningless without method documentation.
In practice, integration of the shoulder — whether you use perpendicular drop or tangent skim — determines what area gets assigned to the main peak versus the impurity table.
One qualification: achieving purity above roughly 98 per cent on a 30-residue peptide is fighting the chemistry of synthesis, not the quality of the purification.
The practical summary: ask for the chromatogram and the method, and ignore the headline number until you have both.
edited 15 Nov 2024 by petra_hovland — corrected a unit error in the worked example