Accepted answer
The honest answer is that published stability data for these specific molecules in a research-grade presentation essentially does not exist, so what you get is extrapolation from the licensed formulations and from general peptide chemistry. That extrapolation is reasonable. It is still extrapolation.
Adsorption to the container is a real loss at low concentration. For a peptide at 0.1 mg/mL in an untreated glass vial, single-digit percentage losses to the wall are plausible; at 5 mg/mL it is negligible. This is one of several reasons not to reconstitute to a very dilute working solution and store it.
Reported and extrapolated stability by condition
| State | Condition | Usable window | Basis |
|---|
| Lyophilised solid | −20 °C, sealed, dry | 24–36 months | Supplier guidance |
| Lyophilised solid | 2–8 °C, sealed | 12–24 months | Supplier guidance |
| Lyophilised solid | 25 °C, sealed | 4–8 weeks | Extrapolated (Arrhenius) |
| Lyophilised solid | 40 °C, sealed | 1–2 weeks | Extrapolated |
| Solution, preserved | 2–8 °C | 28 days | USP microbiological convention |
| Solution, preserved | 25 °C | 3–7 days | Extrapolated |
| Solution, unpreserved | 2–8 °C | 24 hours | USP microbiological convention |
Windows for the solid state are chemical; windows for solution are microbiological and usually shorter than the chemical limit.
For the solid state, residual moisture is the dominant variable. A cake at two per cent water is considerably more stable than the same cake at six per cent, because water is both a reactant in hydrolysis and a plasticiser that lowers the glass transition temperature. This is why a desiccant in the outer packaging is not theatre, and why opening a cold vial in a humid room is a genuine error — you condense water onto the cake.
Where community-submitted samples with known thermal excursions have been tested at Janoshik or Medutest, the recurring finding is that lyophilised material tolerates warm transit far better than intuition suggests, while reconstituted material shipped warm does not. The asymmetry is consistent enough to plan around.
One qualification: none of this addresses sterility. A vial can be chemically pristine and microbiologically compromised, and a chromatogram will not tell you which.
The single highest-value change most people can make is buying a cheap logging thermometer, because it converts an assumption about their storage into a record.
5Two of us worked through this independently and arrived here, so it is at least reproducible. – e_dziedzic 2 months ago 6Worth adding that the method section is where the answer usually is. – otto_brenner 4 months ago add a comment