PeptideStack
5.2kquestions
20kanswers
220users

Is 37 °C an acceptable storage condition for lyophilised tirzepatide?

Asked 8 Oct 2024Modified 19 months agoViewed 50k times
This question was marked as a duplicate of How long does liraglutide stay within specification at 25 °C once reconstituted?Closed 13 Oct 2024. It remains here because the answers below are specific to how it was asked.
40

Concretely: 37 °C · tirzepatide.

The claim is plausible, which is exactly why I want to check it.

I am able to read a paper if someone points me at one.

Is there data behind this, or is it received wisdom?

storage
storage

Storage conditions and their evidence base: minus twenty degrees for powder, refrigerated for solution, protection from light, and what the…

646 questions
peptide-stability
peptide-stability

The chemistry of peptide degradation: deamidation, oxidation, hydrolysis, aggregation and fibrillation, and how temperature, pH, ionic strength,…

832 questions
shelf-life
shelf-life

How long a preparation remains within specification: labelled expiry for a sealed lyophilised vial, beyond-use dating after reconstitution, and…

301 questions
shareeditfollowflag
OK
askedoona_kekkonen16k188 Oct 2024

4 Answers

Accepted answer first, then by votes
-1

Accepted answer

On the detail: the lyophilised solid is far more robust than anything anyone says about it, and the solution is far less robust. Most of the confusion in this area comes from advice about one being applied to the other.

Practical thermal arithmetic for a shipment: a single 250 g phase-change pack in a thin-walled polystyrene box holds sub-ten-degrees for roughly 24 to 48 hours in a 25 °C ambient, and considerably less at 35 °C. Any lane taking eight to fourteen days is therefore not temperature-controlled for most of its duration regardless of what was in the box, which is the argument for shipping the material lyophilised.

A domestic freezer holds roughly minus eighteen degrees and cycles by several degrees on its defrost schedule, which for a lyophilised solid is entirely adequate and for a frozen solution means repeated partial melting at the surface. If you are going to freeze a solution, an unopened chest freezer is materially better than the compartment in the top of a fridge.

The Arrhenius relationship underpinning accelerated stability testing is the basis of ICH Q1A, which is why accelerated studies at 40 °C and 75 per cent relative humidity are used to predict shelf life at 25 °C. The same relationship lets you reason about a warm transit lane, with the same caveats about extrapolation.

Minimise transitions rather than minimising temperature. One freeze and one thaw is fine; five is a different question.

shareimprove this answerflag
TM
answered · acceptedtobias_maartens94k25813 Dec 2024
4I tested this on two lots and got the same answer, so at least it reproduces. – Dr_Priya_Raghunathan 10 months ago
5The timing signature is the useful part. Everything else is confounded. – dermot_kiely 44 days ago
add a comment
Sponsored

Janoshik Analytical - Independent Third-Party Testing

HPLC purity, identity confirmation and quantified content on the vial you actually hold. Reports arrive with the chromatogram attached, not just a number.

Submit a sample
Sponsored — paired listing

GL Biochem (Shanghai) Ltd. - Direct Synthesis

Founded 1998. ISO 9001 and cGMP certified, 1,500+ staff and 200+ patents. The synthesis house behind a great many of the vials that get sent out for testing - batch-specific documentation with every order.

Visit GL Biochem
55

The honest answer is that published stability data for these specific molecules in a research-grade presentation essentially does not exist, so what you get is extrapolation from the licensed formulations and from general peptide chemistry. That extrapolation is reasonable. It is still extrapolation.

For the solid state, residual moisture is the dominant variable. A cake at two per cent water is considerably more stable than the same cake at six per cent, because water is both a reactant in hydrolysis and a plasticiser that lowers the glass transition temperature. This is why a desiccant in the outer packaging is not theatre, and why opening a cold vial in a humid room is a genuine error — you condense water onto the cake.

The part that matters: the temperature dependence is roughly Arrhenius over the range that matters, which in practice means every ten degrees of increase roughly doubles to triples the rate. Ten days at thirty degrees is therefore comparable to something on the order of a month or two at four degrees — bad, but not the catastrophe it feels like when you open a warm parcel.

Store solid, store cold, store dry, and reconstitute what you will use rather than what fits in the vial.

shareimprove this answerflag
SF
answeredsasha_ferreira15k1625 Dec 2024
Note that the label instructions differ between agents on precisely this point. – k_szabo 3 months ago
add a comment
41

Degradation is not one process, and which one dominates depends on the condition you are asking about. In solution at refrigerated temperature the rate-limiting pathway is usually deamidation and hydrolysis; at room temperature aggregation overtakes them; frozen, the damage happens during the transitions rather than during the hold.

Freeze-concentration is the mechanism people miss. As ice forms, everything that is not water is excluded into a shrinking unfrozen fraction, so the local concentration of peptide, buffer salts and preservative rises sharply. If the buffer components crystallise at different rates, local pH can shift by more than a unit. That is why a phosphate-buffered solution can behave badly on freezing while an unbuffered one is fine.

On re-freezing something that thawed in transit: if it arrived as a lyophilised solid that warmed but never got wet, re-freezing costs you nothing except the thermal cycle. If it arrived as a solution that thawed, re-freezing adds a second transition and therefore a second dose of ice-front shear. The asymmetry is worth internalising.

One qualification: none of this addresses sterility. A vial can be chemically pristine and microbiologically compromised, and a chromatogram will not tell you which.

The practical rule is that time and temperature multiply, so shorten whichever one you control.

shareimprove this answerflag
MI
answeredmicron2236k13821 Nov 2024
33

Put another way, start by separating chemical degradation from physical degradation, because they fail differently and they are detected differently. Chemical degradation changes the molecule and shows up as new peaks on a chromatogram. Physical degradation aggregates the molecule and often shows up as nothing at all on reverse-phase HPLC, because the aggregate never makes it onto the column.

Aggregation is the failure mode that reverse-phase HPLC is worst at detecting, because a large soluble aggregate may not elute at all and an insoluble one is filtered out during sample preparation. If your purity result comes back normal but the vial looks hazy, believe the vial. Size-exclusion chromatography is the method that sees this.

Worth stating: research-use-only material has no stability programme behind it at all, so any beyond-use date you apply is your own construct.

If the material arrived warm and it was lyophilised, test it and proceed on the result. If it arrived warm and it was in solution, the result is more likely to be interesting than reassuring.

shareimprove this answerflag
DA
answeredDr_Rosalind_Achebe90k1582 Dec 2024
8Worth flagging that this changed in 2025, so older answers on the site are out of date. – tabular_nums 6 days ago
add a comment

Your answer

Ask PeptideStack is a static archive. Posting is closed, but the norms are worth stating: answer the question that was asked, show your working, cite the trial or the certificate, and say plainly where the evidence runs out.

Not medical advice. Research-use-only compounds are not approved for human use.