Accepted answer
Stated carefully, write the units at every step, because units errors are the failure mode that catches everyone eventually.
Breaking it down further: if a 10 mg vial has 96.5 per cent content, you have 9.65 mg of peptide. Divide that by 2.00 mL and your concentration is 4.825 mg/mL, not 5.00 mg/mL, which is a 3.5 per cent systematic error in every dose calculation.
Reading a lyophilised cake
| Appearance | Interpretation | Action |
|---|
| Intact opaque puck, proud of base | Cycle ran correctly | Proceed |
| Slumped to one side | Shipped before fully dry, or vibration | Usually usable; note it |
| Glassy translucent film | Collapse above glass transition | Test before use |
| Melt-back ring at stopper | Thermal excursion in transit | Test before use |
| No visible cake at all | Very low fill, or nothing there | Weigh it; query the supplier |
Do not use the same needle to pierce the stopper and to administer. The tip is blunted by the stopper, and the hub now contains a dose you are about to lose to dead space anyway.
The Arrhenius relationship for drawing kinetics means that cold solution takes noticeably longer to draw than room-temperature solution.
One qualification: if your arithmetic and someone else's disagree by a factor of ten, one of you has made a unit error, and writing out the units at every step is the diagnostic.
Do the arithmetic twice, ideally with someone else doing it independently.
7This should probably be in the site help pages rather than buried in an answer. – anja_hellstrom 2 months ago 6Good answer, but the confidence interval in the cited trial is wider than implied. – gradient_slope 4 days ago add a comment