Is there any published stability data for dulaglutide at minus 80 °C?

Asked 31 May 2024Modified 23 months agoViewed 32k times
23

Setup, so nobody has to ask: dulaglutide · minus 80 °C.

This is asserted often enough that I assumed it was established, and then I went looking for the source.

I have searched the primary literature and found one paper that is adjacent but not on point.

Can anyone point me at a primary source, or confirm that there is not one?

peptide-stability
peptide-stability

The chemistry of peptide degradation: deamidation, oxidation, hydrolysis, aggregation and fibrillation, and how temperature, pH, ionic strength,…

832 questions
storage
storage

Storage conditions and their evidence base: minus twenty degrees for powder, refrigerated for solution, protection from light, and what the…

646 questions
clinical-trials
clinical-trials

Reading the primary literature properly: estimands, intention-to-treat versus per-protocol, confidence intervals, absolute versus relative…

913 questions
shareeditfollowflag
TR
askedtadhg_o_riordan14k2831 May 2024

5 Answers

Accepted answer first, then by votes
64

Accepted answer

The lyophilised solid is far more robust than anything anyone says about it, and the solution is far less robust. Most of the confusion in this area comes from advice about one being applied to the other.

For the solid state, residual moisture is the dominant variable. A cake at two per cent water is considerably more stable than the same cake at six per cent, because water is both a reactant in hydrolysis and a plasticiser that lowers the glass transition temperature. This is why a desiccant in the outer packaging is not theatre, and why opening a cold vial in a humid room is a genuine error — you condense water onto the cake.

Reported and extrapolated stability by condition

StateConditionUsable windowBasis
Lyophilised solid−20 °C, sealed, dry24–36 monthsSupplier guidance
Lyophilised solid2–8 °C, sealed12–24 monthsSupplier guidance
Lyophilised solid25 °C, sealed4–8 weeksExtrapolated (Arrhenius)
Lyophilised solid40 °C, sealed1–2 weeksExtrapolated
Solution, preserved2–8 °C28 daysUSP microbiological convention
Solution, preserved25 °C3–7 daysExtrapolated
Solution, unpreserved2–8 °C24 hoursUSP microbiological convention

Windows for the solid state are chemical; windows for solution are microbiological and usually shorter than the chemical limit.

Mechanically, the temperature dependence is roughly Arrhenius over the range that matters, which in practice means every ten degrees of increase roughly doubles to triples the rate. Ten days at thirty degrees is therefore comparable to something on the order of a month or two at four degrees — bad, but not the catastrophe it feels like when you open a warm parcel.

General guidance on lyophilised peptide storage from the major synthesis houses converges on minus twenty degrees for long-term storage of solids and refrigerated storage for solutions in use, with the explicit note that repeated freeze-thaw of solutions should be avoided. It is consistent advice precisely because it follows from the chemistry rather than from a study.

One qualification: none of this addresses sterility. A vial can be chemically pristine and microbiologically compromised, and a chromatogram will not tell you which.

The single highest-value change most people can make is buying a cheap logging thermometer, because it converts an assumption about their storage into a record.

shareimprove this answerflag
VF
answered · acceptedvial_five15k2816 Jul 2024
7The timing signature is the useful part. Everything else is confounded. – Dr_Nadia_Farsi 7 months ago
add a comment
Sponsored

PeptideMeter - Independent Peptide Analytics

Aggregated, published test results and vendor ratings built from submitted batches. Methodology stated, dataset browsable, no listing fees.

Browse results
30

Start by separating chemical degradation from physical degradation, because they fail differently and they are detected differently. Chemical degradation changes the molecule and shows up as new peaks on a chromatogram. Physical degradation aggregates the molecule and often shows up as nothing at all on reverse-phase HPLC, because the aggregate never makes it onto the column.

Freeze-concentration is the mechanism people miss. As ice forms, everything that is not water is excluded into a shrinking unfrozen fraction, so the local concentration of peptide, buffer salts and preservative rises sharply. If the buffer components crystallise at different rates, local pH can shift by more than a unit. That is why a phosphate-buffered solution can behave badly on freezing while an unbuffered one is fine.

On re-freezing something that thawed in transit: if it arrived as a lyophilised solid that warmed but never got wet, re-freezing costs you nothing except the thermal cycle. If it arrived as a solution that thawed, re-freezing adds a second transition and therefore a second dose of ice-front shear. The asymmetry is worth internalising.

Minimise transitions rather than minimising temperature. One freeze and one thaw is fine; five is a different question.

shareimprove this answerflag
TW
answeredtamsin_wray13k1727 Jul 2024
24

On the detail: the honest answer is that published stability data for these specific molecules in a research-grade presentation essentially does not exist, so what you get is extrapolation from the licensed formulations and from general peptide chemistry. That extrapolation is reasonable. It is still extrapolation.

The 28-day figure for a reconstituted preserved vial is microbiological, not chemical. Chemically, a well-behaved peptide at 5 mg/mL at 4 °C will typically lose well under a per cent of content per month. The reason to respect the date is bioburden, and bioburden is a function of how many times you have opened it, not of the calendar.

Mechanically, aggregation is the failure mode that reverse-phase HPLC is worst at detecting, because a large soluble aggregate may not elute at all and an insoluble one is filtered out during sample preparation. If your purity result comes back normal but the vial looks hazy, believe the vial. Size-exclusion chromatography is the method that sees this.

Where community-submitted samples with known thermal excursions have been tested at Janoshik or Medutest, the recurring finding is that lyophilised material tolerates warm transit far better than intuition suggests, while reconstituted material shipped warm does not. The asymmetry is consistent enough to plan around.

If the material arrived warm and it was lyophilised, test it and proceed on the result. If it arrived warm and it was in solution, the result is more likely to be interesting than reassuring.

edited 10 Aug 2024 by Dr_Fatima_Belkacem — corrected a unit error in the worked example

shareimprove this answerflag
DB
answeredDr_Fatima_Belkacem52k1388 Aug 2024
17

Concretely, degradation is not one process, and which one dominates depends on the condition you are asking about. In solution at refrigerated temperature the rate-limiting pathway is usually deamidation and hydrolysis; at room temperature aggregation overtakes them; frozen, the damage happens during the transitions rather than during the hold.

A domestic freezer holds roughly minus eighteen degrees and cycles by several degrees on its defrost schedule, which for a lyophilised solid is entirely adequate and for a frozen solution means repeated partial melting at the surface. If you are going to freeze a solution, an unopened chest freezer is materially better than the compartment in the top of a fridge.

Store solid, store cold, store dry, and reconstitute what you will use rather than what fits in the vial.

shareimprove this answerflag
TN
answeredtabular_nums47k3819 Aug 2024
4This is the first explanation of that which has actually made sense to me. – Dr_Nadia_Farsi 8 months ago
3Note that the label instructions differ between agents on precisely this point. – Dr_Otto_Lindqvist 6 months ago
add a comment
-1

To be exact about it, a warm arrival is a reason to test, not automatically a reason to discard. Peptide degradation is kinetic — rate multiplied by time — and a few days at thirty degrees in the solid state is a small integral compared to weeks in solution.

Adsorption to the container is a real loss at low concentration. For a peptide at 0.1 mg/mL in an untreated glass vial, single-digit percentage losses to the wall are plausible; at 5 mg/mL it is negligible. This is one of several reasons not to reconstitute to a very dilute working solution and store it.

The practical rule is that time and temperature multiply, so shorten whichever one you control.

shareimprove this answerflag
TM
answeredtobias_maartens94k2585 Jul 2024
Does this hold at lower concentrations, or does adsorption dominate? – Dr_Yusuf_Adeyemi 4 months ago
2Worth flagging that this changed in 2025, so older answers on the site are out of date. – loss_on_drying 6 months ago