Numbers first: 99.1% · purity figure.
I can parse the result. I am less sure what it licenses me to conclude.
I have deliberately not looked at anyone else’s interpretation yet.
What is the correct interpretation, and what is the common misreading?
Numbers first: 99.1% · purity figure.
I can parse the result. I am less sure what it licenses me to conclude.
I have deliberately not looked at anyone else’s interpretation yet.
What is the correct interpretation, and what is the common misreading?
It helps to be literal here: the method matters more than the vial, which is why specifying a method buys you far more than changing suppliers does.
The fraction of your main peak that is actually your target versus isomers, fragments or related sequences is invisible without complementary identity testing.
| Component | Typical share | Counted in purity? | Counted in content? |
|---|---|---|---|
| Target peptide | 88–94 % | Yes, as main peak | Yes |
| Related impurities | 1–3 % | Yes, as other peaks | No |
| Counter-ion (TFA or acetate) | 2–8 % | No | No |
| Residual water | 2–6 % | No | No |
| Bulking agent, if present | 0–40 % | No | No |
In practice, retention time is sequence-specific and method-specific, so comparing your result to a supplier value using a different method is meaningless without method documentation.
Inter-laboratory studies on identical peptide material routinely find half-a-per-cent to a full-per-cent spreads in reported purity on the same sample.
If you are ranking vendors, specify a method and have all samples tested at the same place.
edited 7 Jul 2024 by tyndall_haze — removed a claim I could not source
Aggregated, published test results and vendor ratings built from submitted batches. Methodology stated, dataset browsable, no listing fees.
Browse resultsGradient slope is the most powerful parameter and almost nobody mentions it, which is why two reports on the same material disagree by a point.
Sample solvent strength affects peak shape — if you inject in strong solvent on a gradient starting in weak solvent, the solvent peak can distort your main peak or create a false shoulder.
Mechanically, mass on column affects detector linearity and peak overlap — overloading broadens peaks and hides neighbours, while underloading improves resolution but loses sensitivity.
Published side-by-side method comparisons show that a two-point difference in purity on the same vial is easily explained by method choice alone.
Compare purity within a single laboratory on the same method, never across laboratories.
Specifically, read the chromatogram before you read the number, because the number without the trace is not a measurement, it is a claim.
Mobile phase additive choice affects ionisation and peak shape — TFA gives sharp peaks but suppresses mass spectrometry signal, formic acid gives worse peaks but preserves signal.
Stated carefully, temperature affects the dynamics of molecular conformation, and if a peptide has proline residues that interconvert on the chromatographic timescale, the peak will split or shoulder at low temperature and collapse at high temperature.
Worth noting that method standardisation is poor in the research-grade space compared to pharmaceutical work, so identical-looking methods can produce different results.
The practical summary: ask for the chromatogram and the method, and ignore the headline number until you have both.
Reporting threshold is convention and not chemistry, which is why two certificates with different thresholds disagree by a tenth of a point or more.
Column pore size affects mass transfer — a 100 Angstrom packing on a 5 kDa peptide restricts diffusion, broadening the peak and potentially hiding small impurities in the shoulders.
The ICH Q3A impurity thresholds and the relevant pharmacopoeial chapters all specify method validation requirements that almost no research-grade certificate claims to meet.
If you are ranking vendors, specify a method and have all samples tested at the same place.
Specifically, purity is a method-dependent figure, and that is not a limitation of the measurement, it is a property of what the measurement actually answers.
Buffer versus acid in the mobile phase changes the ionisation state of basic and acidic residues, shifting retention and selectivity — same vial, potentially different separation.
Compare purity within a single laboratory on the same method, never across laboratories.