Accepted answer
Start by separating chemical degradation from physical degradation, because they fail differently and they are detected differently. Chemical degradation changes the molecule and shows up as new peaks on a chromatogram. Physical degradation aggregates the molecule and often shows up as nothing at all on reverse-phase HPLC, because the aggregate never makes it onto the column.
For the solid state, residual moisture is the dominant variable. A cake at two per cent water is considerably more stable than the same cake at six per cent, because water is both a reactant in hydrolysis and a plasticiser that lowers the glass transition temperature. This is why a desiccant in the outer packaging is not theatre, and why opening a cold vial in a humid room is a genuine error — you condense water onto the cake.
The underlying point is that a domestic freezer holds roughly minus eighteen degrees and cycles by several degrees on its defrost schedule, which for a lyophilised solid is entirely adequate and for a frozen solution means repeated partial melting at the surface. If you are going to freeze a solution, an unopened chest freezer is materially better than the compartment in the top of a fridge.
The licensed semaglutide and tirzepatide presentations carry in-use periods of several weeks at room temperature in their labelling, which is the closest thing to real stability data in this space — and it applies to a buffered, surfactant-containing, preservative-containing formulation, not to a reconstituted research vial.
The limitation is that you cannot detect slow aggregation by eye until it is well advanced, so a clear vial is weak evidence of an intact one.
The single highest-value change most people can make is buying a cheap logging thermometer, because it converts an assumption about their storage into a record.
8For what it is worth, my own result was within half a per cent of this. – nils_karlberg 6 months ago add a comment