Answer first: for a lyophilised solid the cold chain matters far less than people believe, and for a solution it matters far more than they act as though it does.
A pack that arrived hard tells you about the last day of transit only, since it will have melted and, if the ambient dropped, partially refrozen.
The relevant detail is that that is the argument for shipping lyophilised rather than for shipping colder. A dry powder with low residual moisture is stable at ambient for months; the pathways that matter need water.
Phase-change pack hold time is a function of mass, latent heat and insulation, and published figures for small parcels are on the order of one to two days.
Reconstituted material has a genuine cold-chain requirement and it starts the moment water is added.
Buy a logger if you actually want to know. Everything else is inference.