Accepted answer
Specifically, most suppliers test one vial per lot and report the result as lot homogeneity, which is sampling one item from one lot and extrapolating wildly.
If you have reason to suspect inhomogeneity — different appearance in different vials, or a long or warm shipment — testing more vials is the diagnostic move.
Mass shifts and what they usually mean
| Δ mass (Da) | Most likely cause | Distinguishing feature |
|---|
| +1 | Deamidation (Asn or Gln) | New peak, slightly earlier retention |
| −17 | Loss of ammonia | Often with deamidation |
| −18 | Dehydration / succinimide | pH-dependent, reversible |
| +16 | Oxidation (Met, Trp) | Earlier retention, light-related |
| −128 | Missing Gln or Lys | Deletion sequence from synthesis |
| 0 | Isomer: racemisation or scrambling | Same mass, shifted retention |
More usefully, stratified sampling — testing one vial from the top, one from the middle, and one from the bottom of a shipment — is cheap insurance against segregation.
Sampling plans for pharmaceutical manufacturing are defined in ISO 2859 and ANSI Z1.4, and they are based on statistical sampling theory.
The practical summary: a lot number without a sampling statement is a lot number without meaning.