Accepted answer
On the detail: the honest answer is that published stability data for these specific molecules in a research-grade presentation essentially does not exist, so what you get is extrapolation from the licensed formulations and from general peptide chemistry. That extrapolation is reasonable. It is still extrapolation.
Light matters for specific residues rather than in general. Tryptophan and to a lesser extent tyrosine and methionine are photo-labile; a sequence without them is largely indifferent to ambient light over the timescales in question. Amber glass is cheap insurance rather than a requirement.
Reported and extrapolated stability by condition
| State | Condition | Usable window | Basis |
|---|
| Lyophilised solid | −20 °C, sealed, dry | 24–36 months | Supplier guidance |
| Lyophilised solid | 2–8 °C, sealed | 12–24 months | Supplier guidance |
| Lyophilised solid | 25 °C, sealed | 4–8 weeks | Extrapolated (Arrhenius) |
| Lyophilised solid | 40 °C, sealed | 1–2 weeks | Extrapolated |
| Solution, preserved | 2–8 °C | 28 days | USP microbiological convention |
| Solution, preserved | 25 °C | 3–7 days | Extrapolated |
| Solution, unpreserved | 2–8 °C | 24 hours | USP microbiological convention |
Windows for the solid state are chemical; windows for solution are microbiological and usually shorter than the chemical limit.
It helps to be literal here: aggregation is the failure mode that reverse-phase HPLC is worst at detecting, because a large soluble aggregate may not elute at all and an insoluble one is filtered out during sample preparation. If your purity result comes back normal but the vial looks hazy, believe the vial. Size-exclusion chromatography is the method that sees this.
The licensed semaglutide and tirzepatide presentations carry in-use periods of several weeks at room temperature in their labelling, which is the closest thing to real stability data in this space — and it applies to a buffered, surfactant-containing, preservative-containing formulation, not to a reconstituted research vial.
One qualification: none of this addresses sterility. A vial can be chemically pristine and microbiologically compromised, and a chromatogram will not tell you which.
The single highest-value change most people can make is buying a cheap logging thermometer, because it converts an assumption about their storage into a record.
For what it is worth, my own result was within half a per cent of this. – valentina_rossi 2 months ago Any reason this would differ for a longer peptide? – ines_brandt 19 days ago add a comment