Accepted answer
98.4 per cent is at the top of what stepwise synthesis delivers on a chain this long, and it is reachable rather than fictional. Every coupling is high-yielding and none is quantitative, so the deletion and truncation sequences that survive purification are what occupies the remaining 1.6 per cent. Above roughly 98 per cent you are fighting the purification rather than the synthesis, which is why a 98.4 per cent figure on a GLP-1 receptor agonist deserves a method question — column, gradient, wavelength — rather than either belief or dismissal.
On the detail: understanding purity requires separating the chemistry from the method from the reporting convention, and the three are not independent.
Temperature affects the dynamics of molecular conformation, and if a peptide has proline residues that interconvert on the chromatographic timescale, the peak will split or shoulder at low temperature and collapse at high temperature.
What each test answers
| Test | Answers | Does NOT answer |
|---|
| RP-HPLC, area % | What fraction of detected material is the target | How much target is present |
| Quantified content | Milligrams of peptide per vial | What the impurities are |
| ESI-MS identity | Whether the molecular weight matches | Purity, or isomeric substitution |
| Peptide mapping | Sequence, localised to a fragment | Quantity |
| Karl Fischer | Water content of the solid | Solvent content |
| LAL endotoxin | Pyrogen load in EU/mg | Sterility |
| Sterility test | Growth in defined media over 14 days | Endotoxin, or bioburden count |
Mechanically, column pore size affects mass transfer — a 100 Angstrom packing on a 5 kDa peptide restricts diffusion, broadening the peak and potentially hiding small impurities in the shoulders.
Published side-by-side method comparisons show that a two-point difference in purity on the same vial is easily explained by method choice alone.
One qualification: achieving purity above roughly 98 per cent on a 30-residue peptide is fighting the chemistry of synthesis, not the quality of the purification.
Compare purity within a single laboratory on the same method, never across laboratories.