Accepted answer
The hazard ratio is the relative effect. What changes decisions is the absolute effect, and converting between them requires the event rate in the control arm, which is usually in the same table and rarely in the abstract.
HbA1c is a weighted average, not a flat one: roughly half the signal comes from the most recent month. That is why a value drawn six weeks after a change already reflects most of the effect, and why a value drawn during rapid haematological turnover reflects something other than glycaemia.
Headline results, principal programmes
| Trial | Agent | n | Duration | Primary result |
|---|
| STEP 1 | Semaglutide 2.4 mg | 1,961 | 68 wk | −14.9 % vs −2.4 % weight |
| STEP 2 | Semaglutide 2.4 mg, T2DM | 1,210 | 68 wk | −9.6 % vs −3.4 % weight |
| SURMOUNT-1 | Tirzepatide 5/10/15 mg | 2,539 | 72 wk | −15 / −19 / −21 % weight |
| SURMOUNT-4 | Tirzepatide, withdrawal | 670 | 88 wk | Continued loss vs substantial regain |
| SELECT | Semaglutide 2.4 mg | 17,604 | ~40 mo | MACE HR 0.80 (0.72–0.90) |
| FLOW | Semaglutide 1.0 mg, CKD | 3,533 | ~3.4 yr | Renal composite reduced; stopped early |
| SURMOUNT-OSA | Tirzepatide, OSA | 469 | 52 wk | AHI reduced with and without PAP |
Mechanically, liver enzymes are a poor surrogate for hepatic histology in both directions: substantial steatohepatitis with normal transaminases is common, and modest enzyme elevation with minimal fibrosis is common. If the question is fibrosis, the answer comes from a non-invasive score such as FIB-4 or a stiffness measurement, not from ALT.
SURMOUNT-OSA reported reductions in the apnoea-hypopnoea index with tirzepatide in adults with obesity and moderate-to-severe obstructive sleep apnoea, both with and without concurrent positive airway pressure therapy[1].
One qualification: a trial that demonstrates an endpoint at a given dose has demonstrated it at that dose. Extrapolating the endpoint down the dose ladder is an assumption, not a finding.
If the trend across three draws is flat, the difference between draws one and two was noise. Most of what people react to is noise.
5Small correction: the units in the third paragraph should be micrograms, not milligrams. – h_pergande 5 months ago 4Do you have a reference for the last claim? Not disputing it, just want to read it. – lipid_panel_q 3 months ago add a comment