Accepted answer
On the detail: two people working through the same arithmetic independently should get the same answer, and if they do not, someone has made a unit error.
The rounding error accumulates if you round too many times — rounding concentration to 5.0, rounding the dose volume to 0.1 mL, rounding the unit reading to 10 — and the safest approach is to work the full precision and round only the final answer.
Concentration and unit conversion at a glance
| Vial | Diluent | Concentration | 0.25 mg | 0.5 mg | 1 mg | 2.5 mg |
|---|
| 5 mg | 1 mL | 5 mg/mL | 5 u | 10 u | 20 u | 50 u |
| 5 mg | 2 mL | 2.5 mg/mL | 10 u | 20 u | 40 u | 100 u |
| 10 mg | 1 mL | 10 mg/mL | 2.5 u | 5 u | 10 u | 25 u |
| 10 mg | 2 mL | 5 mg/mL | 5 u | 10 u | 20 u | 50 u |
| 10 mg | 3 mL | 3.33 mg/mL | 7.5 u | 15 u | 30 u | 75 u |
Units are U-100 insulin units, where 1 unit = 0.01 mL. Divide dose by concentration for millilitres, then multiply by 100.
The concentration you actually work with is label claim times content fraction divided by actual diluent volume, which is usually not the same as the nominal concentration because content is usually not 100 per cent and you rarely measure the diluent volume to 0.1 mL precision.
Published data on syringe dead space quantifies low-dead-space designs as retaining under 2 µL against 35 µL or more for conventional detachable-needle syringes.
If in doubt, use more diluent and accept the shorter usable window.