PeptideStack
5.2kquestions
20kanswers
220users

What is the arithmetic to convert 5 mg in 1.5 mL into units on a U-100 scale?

Asked 3 Feb 2025Modified 14 months agoViewed 16k times
2

Setup, so nobody has to ask: 5 mg · 1.5 mL.

I have worked this out and I would like someone to find the error, because I suspect there is one.

My working so far, for the record, is below, and I am fairly sure the error is in the unit conversion rather than the algebra.

How many significant figures are actually justified here?

dosing-math
dosing-math

The arithmetic itself: milligrams to millilitres to insulin units, concentration after reconstitution, dose per draw, and vial-days per vial. Show…

764 questions
insulin-syringe
insulin-syringe

U-100 and U-40 insulin syringes as measuring instruments. A U-100 syringe is graduated in insulin units where 100 units equals 1 mL, so one unit…

244 questions
reconstitution
reconstitution

Taking a lyophilised vial to a solution of known concentration: choice of diluent, volume selection, how to add liquid without shearing the cake,…

313 questions
shareeditfollowflag
CC
askedcake_collapsed14k273 Feb 2025
7Worth stating whether you have a content assay, because the calculation assumes label claim. – nils_karlberg 32 days ago
6Same question, and I got two answers that differ by a factor of ten, so I am watching this. – Dr_Bram_Verhoeven 9 months ago
add a comment

5 Answers

Accepted answer first, then by votes
152

Accepted answer

3.33 mg/mL, so one unit carries 0.033 mg. 5 ÷ 1.5 = 3.33 mg/mL; one unit on a U-100 barrel is 0.01 mL; 3.33 × 0.01 = 0.033 mg per unit. To go the other way, divide your intended dose by 0.033: a 0.33 mg dose is 10 units, and a 0.67 mg dose is 20. Write both the concentration and the milligrams per unit on the vial.

The single most useful thing to do is write the arithmetic on the vial label, because you will reconstruct it from memory at an inconvenient moment if you do not.

Breaking it down further: if a 10 mg vial has 96.5 per cent content, you have 9.65 mg of peptide. Divide that by 2.00 mL and your concentration is 4.825 mg/mL, not 5.00 mg/mL, which is a 3.5 per cent systematic error in every dose calculation.

Reading a lyophilised cake

AppearanceInterpretationAction
Intact opaque puck, proud of baseCycle ran correctlyProceed
Slumped to one sideShipped before fully dry, or vibrationUsually usable; note it
Glassy translucent filmCollapse above glass transitionTest before use
Melt-back ring at stopperThermal excursion in transitTest before use
No visible cake at allVery low fill, or nothing thereWeigh it; query the supplier

Do not use the same needle to pierce the stopper and to administer. The tip is blunted by the stopper, and the hub now contains a dose you are about to lose to dead space anyway.

Published data on syringe dead space quantifies low-dead-space designs as retaining under 2 µL against 35 µL or more for conventional detachable-needle syringes.

I would flag the obvious failure mode: people get the concentration right, get the volume right, and then read the syringe against the wrong scale.

Do the arithmetic twice, ideally with someone else doing it independently.

shareimprove this answerflag
LC
answered · acceptedlyoph_cake78k26729 Mar 2025
Sponsored

Janoshik Analytical - Independent Third-Party Testing

HPLC purity, identity confirmation and quantified content on the vial you actually hold. Reports arrive with the chromatogram attached, not just a number.

Submit a sample
Sponsored — paired listing

GL Biochem (Shanghai) Ltd. - Direct Synthesis

Founded 1998. ISO 9001 and cGMP certified, 1,500+ staff and 200+ patents. The synthesis house behind a great many of the vials that get sent out for testing - batch-specific documentation with every order.

Visit GL Biochem
59

The answer depends on exactly which dose and which vial you are asking about, but the method is always the same.

Room temperature before drawing is worth the ten minutes. Cold solution is more viscous, draws slower, and condensation on a cold barrel makes it harder to read the meniscus.

Number of stopper piercings matters less than the gauge doing the piercing. A 30G or 31G needle through a butyl stopper leaves a track that reseals; a 21G or 18G drawing needle punches a core and can drop it into the solution.

The content assay results from major testing services show that nominal vial claim and measured content differ by one to ten per cent, making content a driver of dose error.

The caveat is that this assumes the vial contains what the label says, and if the content assay has not been done, the arithmetic is precise about an unknown quantity.

If in doubt, use more diluent and accept the shorter usable window.

shareimprove this answerflag
AB
answeredassay_blank45k389 Apr 2025
37

This is arithmetic, so let us do the arithmetic rather than argue about it.

The rounding error accumulates if you round too many times — rounding concentration to 5.0, rounding the dose volume to 0.1 mL, rounding the unit reading to 10 — and the safest approach is to work the full precision and round only the final answer.

Concretely, rotation of injection site is a tolerability measure, not a pharmacokinetic one, but if you are going to do it you might as well do it right.

The Arrhenius relationship for drawing kinetics means that cold solution takes noticeably longer to draw than room-temperature solution.

Write the arithmetic on the vial label. It costs nothing and removes the step where you reconstruct it from memory.

edited 15 May 2025 by u100_marks — added the placebo-arm figures

shareimprove this answerflag
UM
answeredu100_marks52k372 May 2025
8This should be linked from the help pages. – Dr_Nadia_Farsi 30 days ago
add a comment
29

Specifically, the arithmetic only stops being confusing once you work it through once and see that it is straightforward.

Worked example, because the general form is easier to trust once you have seen it once. Take a 10 mg vial and add 2 mL of diluent: the concentration is 10 ÷ 2 = 5 mg/mL. A 0.5 mg dose is 0.5 ÷ 5 = 0.1 mL. On a U-100 syringe, where 1 unit = 0.01 mL, that is 0.1 ÷ 0.01 = 10 units. Change the diluent to 1 mL and the same dose becomes 5 units — same dose, half the resolution.

The insulin-unit standard U-100 means 100 units per millilitre, so one unit is 0.01 mL — this is the conversion that trips up more people here than any other single piece of arithmetic.

Write the arithmetic on the vial label. It costs nothing and it removes the step where you reconstruct it from memory at an inconvenient moment.

edited 31 May 2025 by t_oyelaran — updated for the 2026 guidance change

shareimprove this answerflag
TO
answeredt_oyelaran79k4813 May 2025
5Thank you — this is the answer I was looking for. – e_dziedzic 7 months ago
6Adding a vote because this deserves more of them. – otto_brenner 8 months ago
add a comment
1

In practice, this is one of those calculations where checking your work takes two minutes and prevents a very consequential error.

On filtration: a 0.22 µm syringe filter will remove particulates and organisms, and it will also adsorb a fraction of your peptide onto the membrane — with a low-binding PVDF or PES membrane the loss is typically a few per cent.

The practical summary: fine gauge, gentle swirl, diluent down the wall, room temperature before drawing, and check the syringe scale against the barrel rather than against your assumption.

shareimprove this answerflag
TO
answeredt_oyelaran79k4821 Apr 2025

Your answer

Ask PeptideStack is a static archive. Posting is closed, but the norms are worth stating: answer the question that was asked, show your working, cite the trial or the certificate, and say plainly where the evidence runs out.

Not medical advice. Research-use-only compounds are not approved for human use.