Accepted answer
Dose arithmetic has three parts: concentration from vial content and diluent, volume from dose and concentration, and units from volume and syringe scale.
The rounding error accumulates if you round too many times — rounding concentration to 5.0, rounding the dose volume to 0.1 mL, rounding the unit reading to 10 — and the safest approach is to work the full precision and round only the final answer.
Concentration and unit conversion at a glance
| Vial | Diluent | Concentration | 0.25 mg | 0.5 mg | 1 mg | 2.5 mg |
|---|
| 5 mg | 1 mL | 5 mg/mL | 5 u | 10 u | 20 u | 50 u |
| 5 mg | 2 mL | 2.5 mg/mL | 10 u | 20 u | 40 u | 100 u |
| 10 mg | 1 mL | 10 mg/mL | 2.5 u | 5 u | 10 u | 25 u |
| 10 mg | 2 mL | 5 mg/mL | 5 u | 10 u | 20 u | 50 u |
| 10 mg | 3 mL | 3.33 mg/mL | 7.5 u | 15 u | 30 u | 75 u |
Units are U-100 insulin units, where 1 unit = 0.01 mL. Divide dose by concentration for millilitres, then multiply by 100.
Dead space quantified: a fixed-needle insulin syringe holds roughly 3 to 5 µL in the hub and needle after the plunger bottoms out. A luer-lock syringe with a detachable needle holds 35 to 100 µL depending on the hub design. At 5 mg/mL that is 15 to 25 µg lost per draw on the insulin syringe and 175 to 500 µg on the luer-lock — which over ten draws is the difference between losing a rounding error and losing half a milligram.
The insulin-unit standard U-100 means 100 units per millilitre, so one unit is 0.01 mL — this is the conversion that trips up more people here than any other single piece of arithmetic.
The caveat is that this assumes the vial contains what the label says, and if the content assay has not been done, the arithmetic is precise about an unknown quantity.
Write the arithmetic on the vial label. It costs nothing and removes the step where you reconstruct it from memory.