Because temperature enters the rate constant through an exponential, so equal steps in temperature multiply the rate instead of adding to it. Arrhenius puts the rate proportional to exp(−Ea/RT); the working approximation is a doubling per 10 K, which takes 5, 15, 25 and 35 °C to multipliers of 1, 2, 4 and 8. The steps in temperature are equal and the steps in rate are not, and that is the whole of the observation. At room temperature the same rule gives about 3.4 times the refrigerated rate, and another 10 K would roughly double it again. A stereocentre inverts. Identical mass, identical formula; only a chiral method or a peptide map with a chiral digestion sees it at all. Ea differs by route, so the ranking of routes changes with temperature too — which is why accelerated data extrapolates badly and why nobody should read a 40 °C study as a fast version of a 5 °C one.
Asparagine and glutamine are the deamidation risk, and methionine is the oxidation risk.
Light exposure matters for tryptophan-containing sequences and for anything with a chromophore. Amber vials and a closed box are free mitigations.
Aggregation is physical: peptides unfold at air-liquid interfaces and associate. Shaking maximises that interface, which is why swirling and shaking produce visibly different outcomes on the same vial.
Sequence decides which pathways are even available. Check the residues.
edited 11 Apr 2025 by sian_llewellyn — clarified the distinction between purity and content