PeptideStack
5.2kquestions
20kanswers
220users

Is a domestic freezer good enough for storing reconstituted liraglutide?

Asked 14 Mar 2024Modified 2.1 years agoViewed 70k times
34

The case in front of me: a domestic freezer · liraglutide.

The failure mode I am trying to avoid is making this decision emotionally.

I have twelve months in view and I would like the plan to survive that long.

How would you structure this, and what thresholds would you set in advance?

storage
storage

Storage conditions and their evidence base: minus twenty degrees for powder, refrigerated for solution, protection from light, and what the…

646 questions
cold-chain
cold-chain

Keeping material within a temperature window from manufacture to use: phase-change packs versus dry ice, thermal mass, transit-lane temperature…

524 questions
harm-reduction
harm-reduction

Reducing avoidable risk where a decision has already been made: independent verification before use, sterility practice, dose arithmetic checked…

445 questions
shareeditfollowflag
TW
askedtamsin_wray13k1714 Mar 2024
Confirming from the other direction: I did the wrong thing and got exactly the predicted outcome. – Dr_Colm_Fitzhenry 4 months ago
Is there a reason to prefer the second method over the first, other than cost? – bac_or_bust 3 months ago
add a comment

5 Answers

Accepted answer first, then by votes
29

Accepted answer

More usefully, the lyophilised solid is far more robust than anything anyone says about it, and the solution is far less robust. Most of the confusion in this area comes from advice about one being applied to the other.

Freeze-concentration is the mechanism people miss. As ice forms, everything that is not water is excluded into a shrinking unfrozen fraction, so the local concentration of peptide, buffer salts and preservative rises sharply. If the buffer components crystallise at different rates, local pH can shift by more than a unit. That is why a phosphate-buffered solution can behave badly on freezing while an unbuffered one is fine.

For the solid state, residual moisture is the dominant variable. A cake at two per cent water is considerably more stable than the same cake at six per cent, because water is both a reactant in hydrolysis and a plasticiser that lowers the glass transition temperature. This is why a desiccant in the outer packaging is not theatre, and why opening a cold vial in a humid room is a genuine error — you condense water onto the cake.

The licensed semaglutide and tirzepatide presentations carry in-use periods of several weeks at room temperature in their labelling, which is the closest thing to real stability data in this space — and it applies to a buffered, surfactant-containing, preservative-containing formulation, not to a reconstituted research vial.

The limitation is that you cannot detect slow aggregation by eye until it is well advanced, so a clear vial is weak evidence of an intact one.

The single highest-value change most people can make is buying a cheap logging thermometer, because it converts an assumption about their storage into a record.

shareimprove this answerflag
GP
answered · acceptedg_paskevicius44k3828 Jun 2024
Good answer, but the confidence interval in the cited trial is wider than implied. – lyoph_cake 8 months ago
add a comment
Sponsored

Sigma-Aldrich - Certified Reference Materials

Analytical standards and reagents with traceable certificates. Every quantitative result you read inherits the accuracy of the standard behind it.

Shop standards
26

Start by separating chemical degradation from physical degradation, because they fail differently and they are detected differently. Chemical degradation changes the molecule and shows up as new peaks on a chromatogram. Physical degradation aggregates the molecule and often shows up as nothing at all on reverse-phase HPLC, because the aggregate never makes it onto the column.

A domestic freezer holds roughly minus eighteen degrees and cycles by several degrees on its defrost schedule, which for a lyophilised solid is entirely adequate and for a frozen solution means repeated partial melting at the surface. If you are going to freeze a solution, an unopened chest freezer is materially better than the compartment in the top of a fridge.

To be exact about it, practical thermal arithmetic for a shipment: a single 250 g phase-change pack in a thin-walled polystyrene box holds sub-ten-degrees for roughly 24 to 48 hours in a 25 °C ambient, and considerably less at 35 °C. Any lane taking eight to fourteen days is therefore not temperature-controlled for most of its duration regardless of what was in the box, which is the argument for shipping the material lyophilised.

Worth stating: research-use-only material has no stability programme behind it at all, so any beyond-use date you apply is your own construct.

The practical rule is that time and temperature multiply, so shorten whichever one you control.

shareimprove this answerflag
ND
answerednynke_dekker18k2817 Jun 2024
6Small correction: the units in the third paragraph should be micrograms, not milligrams. – j_wierzbicki 9 days ago
7Do you have a reference for the last claim? Not disputing it, just want to read it. – ekaterina_volk 2 months ago
add a comment
8

Freeze-thaw damage happens at the moving ice front, not at the storage temperature. Once the sample is frozen solid and cold, very little is happening. The damage is done during freezing and thawing, which is why the number of cycles matters and the duration of the hold mostly does not.

On re-freezing something that thawed in transit: if it arrived as a lyophilised solid that warmed but never got wet, re-freezing costs you nothing except the thermal cycle. If it arrived as a solution that thawed, re-freezing adds a second transition and therefore a second dose of ice-front shear. The asymmetry is worth internalising.

The temperature dependence is roughly Arrhenius over the range that matters, which in practice means every ten degrees of increase roughly doubles to triples the rate. Ten days at thirty degrees is therefore comparable to something on the order of a month or two at four degrees — bad, but not the catastrophe it feels like when you open a warm parcel.

Deamidation kinetics for asparagine in peptides are well characterised and strongly sequence-dependent: the residue following the asparagine dominates the rate, with glycine and serine at the n+1 position accelerating it by an order of magnitude relative to bulkier residues. That is why two peptides in the same buffer at the same temperature can have quite different shelf lives.

Store solid, store cold, store dry, and reconstitute what you will use rather than what fits in the vial.

shareimprove this answerflag
JE
answeredjonas_ekstrom18k286 Jun 2024
6

A warm arrival is a reason to test, not automatically a reason to discard. Peptide degradation is kinetic — rate multiplied by time — and a few days at thirty degrees in the solid state is a small integral compared to weeks in solution.

Adsorption to the container is a real loss at low concentration. For a peptide at 0.1 mg/mL in an untreated glass vial, single-digit percentage losses to the wall are plausible; at 5 mg/mL it is negligible. This is one of several reasons not to reconstitute to a very dilute working solution and store it.

If the material arrived warm and it was lyophilised, test it and proceed on the result. If it arrived warm and it was in solution, the result is more likely to be interesting than reassuring.

edited 2 May 2024 by bufferline42 — added the method parameters

shareimprove this answerflag
BU
answeredbufferline4249k1383 Apr 2024
-2

The honest answer is that published stability data for these specific molecules in a research-grade presentation essentially does not exist, so what you get is extrapolation from the licensed formulations and from general peptide chemistry. That extrapolation is reasonable. It is still extrapolation.

Light matters for specific residues rather than in general. Tryptophan and to a lesser extent tyrosine and methionine are photo-labile; a sequence without them is largely indifferent to ambient light over the timescales in question. Amber glass is cheap insurance rather than a requirement.

The Arrhenius relationship underpinning accelerated stability testing is the basis of ICH Q1A, which is why accelerated studies at 40 °C and 75 per cent relative humidity are used to predict shelf life at 25 °C. The same relationship lets you reason about a warm transit lane, with the same caveats about extrapolation.

Minimise transitions rather than minimising temperature. One freeze and one thaw is fine; five is a different question.

edited 18 Jun 2024 by ines_brandt — added the citation requested in comments

shareimprove this answerflag
IB
answeredines_brandt93k24826 May 2024

Your answer

Ask PeptideStack is a static archive. Posting is closed, but the norms are worth stating: answer the question that was asked, show your working, cite the trial or the certificate, and say plainly where the evidence runs out.

Not medical advice. Research-use-only compounds are not approved for human use.