PeptideStack
5.2kquestions
20kanswers
220users

Is a 98.4% result from Janoshik comparable to 98.2% from Medutest?

Asked 26 Nov 2024Modified 17 months agoViewed 19k times
9

Details up front: 98.4% · Janoshik · 98.2% · Medutest.

I want to know what the trade-off actually is rather than which option is fashionable.

I would rather have a defensible reason than a marginal improvement.

So which one, and on what grounds?

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

833 questions
batch-testing
batch-testing

Testing at the batch or lot level: sampling plans, how many vials from a lot need testing to say anything about the lot, and the difference…

910 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

185 questions
janoshik
janoshik

Janoshik Analytical, an independent third-party testing laboratory widely used by this community for HPLC purity, identity and quantified content…

139 questions
medutest
medutest

Medutest, one of four independent testing and verification services referenced throughout this site. Use this tag for its methods, its report…

126 questions
shareeditfollowflag
DV
askeddead_volume56k4826 Nov 2024
5Same question came up on a different supplier and the answer was entirely about the method. – kelvin_lam 3 months ago
add a comment

3 Answers

Accepted answer first, then by votes
16

Accepted answer

98.4 and 98.2 are 0.2 percentage points apart, which sounds small until you restate it as impurity. Janoshik is leaving 1.6 per cent of the detected area unassigned and Medutest 1.8 per cent — a factor of 1.13 between them. The impurity fraction is the quantity that moves when a method changes, and it is the one worth arguing about; the headline is just its complement. Comparable means same column chemistry, same gradient slope, same detection wavelength, same integration convention. Until you have those four from both laboratories, 98.4 and 98.2 are two measurements of slightly different quantities that happen to share a unit.

The method matters more than the vial, which is why specifying a method buys you far more than changing suppliers does.

Gradient slope controls resolution, and gentler slopes resolve co-eluting impurities into separate peaks — so the better method reports the worse purity number.

Mass shifts and what they usually mean

Δ mass (Da)Most likely causeDistinguishing feature
+1Deamidation (Asn or Gln)New peak, slightly earlier retention
−17Loss of ammoniaOften with deamidation
−18Dehydration / succinimidepH-dependent, reversible
+16Oxidation (Met, Trp)Earlier retention, light-related
−128Missing Gln or LysDeletion sequence from synthesis
0Isomer: racemisation or scramblingSame mass, shifted retention

Stated carefully, buffer versus acid in the mobile phase changes the ionisation state of basic and acidic residues, shifting retention and selectivity — same vial, potentially different separation.

Inter-laboratory studies on identical peptide material routinely find half-a-per-cent to a full-per-cent spreads in reported purity on the same sample.

The caveat is that purity without identity is only half an answer — a high purity does not mean the peak is actually what you think it is.

The practical summary: ask for the chromatogram and the method, and ignore the headline number until you have both.

shareimprove this answerflag
M4
answered · acceptedmz_4113101k3584 Dec 2024
4Two of us submitted the same lot to different laboratories and got results a tenth apart. – gel_pack_warm 7 months ago
add a comment
Sponsored

Sigma-Aldrich - Certified Reference Materials

Analytical standards and reagents with traceable certificates. Every quantitative result you read inherits the accuracy of the standard behind it.

Shop standards
12

Gradient slope is the most powerful parameter and almost nobody mentions it, which is why two reports on the same material disagree by a point.

Mobile phase additive choice affects ionisation and peak shape — TFA gives sharp peaks but suppresses mass spectrometry signal, formic acid gives worse peaks but preserves signal.

Temperature affects the dynamics of molecular conformation, and if a peptide has proline residues that interconvert on the chromatographic timescale, the peak will split or shoulder at low temperature and collapse at high temperature.

If you are ranking vendors, specify a method and have all samples tested at the same place.

shareimprove this answerflag
AL
answereda_lindgren58k24811 Mar 2025
9

The honest answer is that the achievable range of plausible purity figures for a given vial is wider than most people expect.

Detection wavelength matters because 214 nm sees the peptide backbone while 280 nm sees only aromatic side chains — so truncation impurities lacking a tryptophan are invisible at 280 nm.

On the detail: mass on column affects detector linearity and peak overlap — overloading broadens peaks and hides neighbours, while underloading improves resolution but loses sensitivity.

I would be careful about over-reading a single measurement — treat it as a data point, not as ground truth.

Compare purity within a single laboratory on the same method, never across laboratories.

edited 6 Mar 2025 by RP_C18 — expanded the table to cover the lower concentration

shareimprove this answerflag
RC
answeredRP_C18105k34828 Feb 2025
3Thank you — this is the answer I was looking for. – bac_or_bust 2 months ago
4The distinction between purity and content cannot be repeated often enough here. – Dr_Colm_Fitzhenry 4 months ago
add a comment

Your answer

Ask PeptideStack is a static archive. Posting is closed, but the norms are worth stating: answer the question that was asked, show your working, cite the trial or the certificate, and say plainly where the evidence runs out.

Not medical advice. Research-use-only compounds are not approved for human use.