Accepted answer
The relevant detail is that a single laboratory value is a point on a noisy curve. What you want is a trend across at least three draws under comparable conditions, and "comparable" is doing a lot of work in that sentence.
The early fall in estimated glomerular filtration rate on treatment is haemodynamic rather than structural. Reduced intraglomerular pressure lowers the filtration rate acutely and preserves the glomerulus chronically — the same pattern seen with renin-angiotensin blockade and with SGLT2 inhibition. A dip of a few millilitres per minute in the first weeks, followed by a shallower long-term slope, is the desired trajectory, not a warning sign.
Headline results, principal programmes
| Trial | Agent | n | Duration | Primary result |
|---|
| STEP 1 | Semaglutide 2.4 mg | 1,961 | 68 wk | −14.9 % vs −2.4 % weight |
| STEP 2 | Semaglutide 2.4 mg, T2DM | 1,210 | 68 wk | −9.6 % vs −3.4 % weight |
| SURMOUNT-1 | Tirzepatide 5/10/15 mg | 2,539 | 72 wk | −15 / −19 / −21 % weight |
| SURMOUNT-4 | Tirzepatide, withdrawal | 670 | 88 wk | Continued loss vs substantial regain |
| SELECT | Semaglutide 2.4 mg | 17,604 | ~40 mo | MACE HR 0.80 (0.72–0.90) |
| FLOW | Semaglutide 1.0 mg, CKD | 3,533 | ~3.4 yr | Renal composite reduced; stopped early |
| SURMOUNT-OSA | Tirzepatide, OSA | 469 | 52 wk | AHI reduced with and without PAP |
The rodent thyroid C-cell findings that generated the labelled warning appear to be species-specific: rodent C-cells express GLP-1 receptors at high density, human C-cells at very low density, and human calcitonin data across large trial populations has not reproduced the signal. A family history of medullary thyroid carcinoma or MEN2 is nonetheless a genuine contraindication rather than a theoretical one.
SURMOUNT-OSA reported reductions in the apnoea-hypopnoea index with tirzepatide in adults with obesity and moderate-to-severe obstructive sleep apnoea, both with and without concurrent positive airway pressure therapy[1].
One qualification: a trial that demonstrates an endpoint at a given dose has demonstrated it at that dose. Extrapolating the endpoint down the dose ladder is an assumption, not a finding.
If the trend across three draws is flat, the difference between draws one and two was noise. Most of what people react to is noise.
edited 7 Jul 2025 by ines_brandt — added a caveat about sampling
4I have seen exactly this failure mode twice and both times it was the diluent. – orla_sheridan 5 months ago 3The distinction between purity and content cannot be repeated often enough here. – orla_ferriter 3 months ago add a comment