PeptideStack
5.2kquestions
20kanswers
220users

Is LDL-C a better monitoring choice than triglycerides on semaglutide?

Asked 11 Aug 2024Modified 22 months agoViewed 36k times
40

Stated plainly: LDL-C · triglycerides · semaglutide.

Both of these get recommended confidently by different people, which suggests neither is obviously right.

My constraints are cost, measurement resolution and how much handling I am prepared to do — in roughly that order.

Under what conditions does the answer flip?

bloodwork
bloodwork

Laboratory monitoring: which panels are worth ordering, sensible intervals, reference-range versus optimal-range arguments, and how to read a…

284 questions
kidney-function
kidney-function

eGFR, creatinine, cystatin C and albuminuria: the acute haemodynamic dip that is not injury, the renal outcome data from the FLOW programme, and…

100 questions
lipids
lipids

Lipid response on treatment: triglycerides, LDL-C, non-HDL-C, ApoB and Lp(a), which of them move with weight loss, and why a fasting panel drawn…

112 questions
shareeditfollowflag
JF
askedjuliette_farnese12k2811 Aug 2024

5 Answers

Accepted answer first, then by votes
152

Accepted answer

To be exact about it, the hazard ratio is the relative effect. What changes decisions is the absolute effect, and converting between them requires the event rate in the control arm, which is usually in the same table and rarely in the abstract.

The early fall in estimated glomerular filtration rate on treatment is haemodynamic rather than structural. Reduced intraglomerular pressure lowers the filtration rate acutely and preserves the glomerulus chronically — the same pattern seen with renin-angiotensin blockade and with SGLT2 inhibition. A dip of a few millilitres per minute in the first weeks, followed by a shallower long-term slope, is the desired trajectory, not a warning sign.

Headline results, principal programmes

TrialAgentnDurationPrimary result
STEP 1Semaglutide 2.4 mg1,96168 wk−14.9 % vs −2.4 % weight
STEP 2Semaglutide 2.4 mg, T2DM1,21068 wk−9.6 % vs −3.4 % weight
SURMOUNT-1Tirzepatide 5/10/15 mg2,53972 wk−15 / −19 / −21 % weight
SURMOUNT-4Tirzepatide, withdrawal67088 wkContinued loss vs substantial regain
SELECTSemaglutide 2.4 mg17,604~40 moMACE HR 0.80 (0.72–0.90)
FLOWSemaglutide 1.0 mg, CKD3,533~3.4 yrRenal composite reduced; stopped early
SURMOUNT-OSATirzepatide, OSA46952 wkAHI reduced with and without PAP

Specifically, liver enzymes are a poor surrogate for hepatic histology in both directions: substantial steatohepatitis with normal transaminases is common, and modest enzyme elevation with minimal fibrosis is common. If the question is fibrosis, the answer comes from a non-invasive score such as FIB-4 or a stiffness measurement, not from ALT.

FLOW tested a composite renal endpoint — kidney failure, sustained 50 per cent eGFR decline, or renal or cardiovascular death — in type 2 diabetes with chronic kidney disease, and was stopped early for efficacy[1].

I would resist reading a subgroup finding as a result. Subgroups in these trials were not powered, and a striking subgroup in a large trial is the expected consequence of multiplicity.

If the trend across three draws is flat, the difference between draws one and two was noise. Most of what people react to is noise.

shareimprove this answerflag
VI
answered · acceptedvialroom87k14817 Aug 2024
Sponsored

Janoshik Analytical - Independent Third-Party Testing

HPLC purity, identity confirmation and quantified content on the vial you actually hold. Reports arrive with the chromatogram attached, not just a number.

Submit a sample
Sponsored — paired listing

GL Biochem (Shanghai) Ltd. - Direct Synthesis

Founded 1998. ISO 9001 and cGMP certified, 1,500+ staff and 200+ patents. The synthesis house behind a great many of the vials that get sent out for testing - batch-specific documentation with every order.

Visit GL Biochem
59

The underlying point is that a single laboratory value is a point on a noisy curve. What you want is a trend across at least three draws under comparable conditions, and "comparable" is doing a lot of work in that sentence.

The rodent thyroid C-cell findings that generated the labelled warning appear to be species-specific: rodent C-cells express GLP-1 receptors at high density, human C-cells at very low density, and human calcitonin data across large trial populations has not reproduced the signal. A family history of medullary thyroid carcinoma or MEN2 is nonetheless a genuine contraindication rather than a theoretical one.

A network meta-analysis can rank agents that were never compared directly, but only under a transitivity assumption — that the trials being linked are similar enough in population, duration and endpoint definition for the indirect comparison to hold. In this field that assumption is often visibly violated, which is why indirect rankings should be read as hypotheses.

None of this replaces a clinician who can see the whole picture, and the whole picture is usually where the answer is.

shareimprove this answerflag
MS
answeredmarta_szymanska17k3828 Aug 2024
2Is there a reason to prefer the second method over the first, other than cost? – cake_intact 5 months ago
add a comment
47

The relevant detail is that this is a question about what the trial was designed to answer, and the honest response is that it was not designed to answer this.

HbA1c is a weighted average, not a flat one: roughly half the signal comes from the most recent month. That is why a value drawn six weeks after a change already reflects most of the effect, and why a value drawn during rapid haematological turnover reflects something other than glycaemia.

It helps to be literal here: estimated average glucose from HbA1c: eAG in mg/dL = 28.7 × A1c − 46.7, or in mmol/L, 1.59 × A1c − 2.59. An A1c of 6.5 per cent is therefore about 140 mg/dL or 7.8 mmol/L. The relationship is a population regression, so an individual can sit well off the line.

SURMOUNT-1 reported mean weight reductions of approximately 15, 19 and 21 per cent at tirzepatide 5, 10 and 15 mg respectively at 72 weeks[1].

The papers are readable. Read the paper rather than the summary of the paper, especially where the summary is enthusiastic.

shareimprove this answerflag
WC
answeredwren_calloway14k188 Sept 2024
5This should probably be in the site help pages rather than buried in an answer. – ben_akintola 4 months ago
6Good answer, but the confidence interval in the cited trial is wider than implied. – tess_amankwah 6 months ago
add a comment
37

It helps to be literal here: the confidence interval is the informative part. A point estimate with an interval spanning no effect is a different object from the same point estimate with a tight interval, and the abstract presents them identically.

A fasting lipid panel drawn during rapid weight loss reads oddly for a mechanical reason: mobilised adipose tissue delivers free fatty acids to the liver, and hepatic triglyceride export rises. Triglycerides can transiently increase while the person is doing exactly the right thing. Draw the panel when weight has been stable for a few weeks if you want an interpretable number.

The caveat is the population. Trial participants were screened, monitored and supported; the effect size in an unmonitored setting is not the trial effect size, and it is not obvious in which direction the difference runs.

Read the confidence interval, read the estimand, and compute the absolute effect yourself. It takes two minutes and it changes how the result feels.

shareimprove this answerflag
DH
answeredDr_Wren_Halliday40k3820 Sept 2024
2Worth flagging that this changed in 2025, so older answers on the site are out of date. – Dr_Colm_Fitzhenry 6 months ago
add a comment
29

Read the estimand before the effect size. Almost every apparent contradiction between two published figures from the same trial resolves once you notice that one is a trial-product estimand and the other is a treatment-policy estimand.

ApoB and LDL-C disagree because they measure different things: LDL-C is the cholesterol mass carried in the LDL fraction, ApoB is a count of atherogenic particles. Small dense particles carry less cholesterol each, so a person with many small particles has a concordantly higher ApoB than their LDL-C suggests. When they disagree, ApoB is the better risk marker.

Convert everything to an absolute effect before you compare two interventions. Relative effects are not comparable across different baseline risks.

shareimprove this answerflag
NO
answerednkem_obiora46k381 Oct 2024

Your answer

Ask PeptideStack is a static archive. Posting is closed, but the norms are worth stating: answer the question that was asked, show your working, cite the trial or the certificate, and say plainly where the evidence runs out.