PeptideStack
5.2kquestions
20kanswers
220users

purity

Page 9 of 33 · 788 questions tagged purity.

788 questions · sorted by votes · page 9 of 33

27 votes 5 answers27k views
How do I compute the +4 charge state m/z for a peptide of 3751.0 Da?

The specifics, since they change the answer: +4 · 3751.0 Da. I would rather understand the derivation than memorise the outcome. Two people I asked gave two answers…

mass-spec
mass-spec

Mass spectrometry for identity confirmation: electrospray ionisation, multiple charge states, monoisotopic versus average mass, deconvolution, and…

38 questions
dosing-math
dosing-math

The arithmetic itself: milligrams to millilitres to insulin units, concentration after reconstitution, dose per draw, and vial-days per vial. Show…

811 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
asked by lyoph_cake 95k · 18 months ago
27 votes 5 answers26k views
How do I reconcile 95.2% from VendorInvestigate with 97.9% from the supplier?

The case in front of me: 95.2% · VendorInvestigate · 97.9%. I have two candidate explanations and no way to distinguish them. The same procedure has worked without…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
batch-testing
batch-testing

Testing at the batch or lot level: sampling plans, how many vials from a lot need testing to say anything about the lot, and the difference…

865 questions
coa
coa

Certificates of analysis: what fields a useful one carries, how to tell a real analytical report from a marketing document, batch and lot…

749 questions
asked by dana_wexler 15k · 10 months ago
27 votes 5 answers25k views
Is a 95.2% result from Medutest comparable to 96.8% from Janoshik?

Setup, so nobody has to ask: 95.2% · Medutest · 96.8% · Janoshik. I suspect the honest answer is that it depends, in which case I would like to know on what. Assume I…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
batch-testing
batch-testing

Testing at the batch or lot level: sampling plans, how many vials from a lot need testing to say anything about the lot, and the difference…

865 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

179 questions
asked by k_szabo 45k · 2.0 years ago
27 votes 5 answers25k views
Why is acetate the counter-ion on some lots and TFA on others?

I am comparing a supplier certificate against an independent result on the same lot. The empirical answer seems settled. The explanation does not. If the honest…

acetate-content
acetate-content

Counter-ion content, most often acetate or trifluoroacetate, and why it matters: the counter-ion and residual water are part of the gross mass you…

87 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
residual-solvent
residual-solvent

Solvents left behind by synthesis and purification - acetonitrile, TFA, DMF, DCM - their ICH limits, how they are measured by headspace GC, and…

14 questions
asked by Dr_Ilse_Vandenberg 78k · 2.0 years ago
27 votes 3 answers24k views
What does peptide mapping add for ecnoglutide that a purity figure does not?

The particulars: peptide mapping · ecnoglutide. The comparison I want does not seem to exist anywhere in a form I can evaluate. I have read the arguments for each and…

content-assay
content-assay

Quantified content: how many milligrams of peptide are actually in the vial, measured against a calibrated reference standard. A separate test…

438 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
coa
coa

Certificates of analysis: what fields a useful one carries, how to tell a real analytical report from a marketing document, batch and lot…

749 questions
asked by pk_curve 12k · 13 months ago
27 votes 5 answers23k views
What does 99.1% purity on a C4 column actually tell me about a retatrutide vial?

The case in front of me: 99.1% · a C4 column · retatrutide. I would like to know the limits of what can be inferred from this. What I am trying to avoid is…

hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

466 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
coa
coa

Certificates of analysis: what fields a useful one carries, how to tell a real analytical report from a marketing document, batch and lot…

749 questions
asked by bounty_hunter_q 18k · 23 months ago
27 votes 5 answers22k views
What does an HPLC purity test add for retatrutide that a purity figure does not?

Details up front: an HPLC purity test · retatrutide. I have used one of these for a while and I am considering switching, which requires a reason. What I care about…

content-assay
content-assay

Quantified content: how many milligrams of peptide are actually in the vial, measured against a calibrated reference standard. A separate test…

438 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
coa
coa

Certificates of analysis: what fields a useful one carries, how to tell a real analytical report from a marketing document, batch and lot…

749 questions
asked by elke_brunner 14k · 8 months ago
27 votes5 answers21k views
Does an ammonium formate mobile phase change the purity number I get for liraglutide on a C8 column?

Concretely: an ammonium formate mobile phase · liraglutide · a C8 column. This is one of those things that everyone repeats and nobody derives. This matters…

hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

466 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

179 questions
asked by assay_blank 39k · 9 months ago
27 votes 5 answers21k views
What counter-ion should I expect on an SWB retatrutide lot?

Numbers first: SWB · retatrutide. This is presented as though it settles something, and I am not convinced it does. I have two documents that appear to disagree,…

acetate-content
acetate-content

Counter-ion content, most often acetate or trifluoroacetate, and why it matters: the counter-ion and residual water are part of the gross mass you…

87 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
content-assay
content-assay

Quantified content: how many milligrams of peptide are actually in the vial, measured against a calibrated reference standard. A separate test…

438 questions
asked by ekaterina_volk 16k · 7 months ago
27 votes5 answers19k views
What does 96.8% purity on a C4 column actually tell me about an orforglipron vial?

The case in front of me: 96.8% · a C4 column · orforglipron. The figures are clear enough; the question is what they mean and what they do not. I can supply the…

hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

466 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
coa
coa

Certificates of analysis: what fields a useful one carries, how to tell a real analytical report from a marketing document, batch and lot…

749 questions
asked by g_paskevicius 44k · 2.1 years ago
27 votes0 answers17k views
Why would PeptideMeter report 97.6% where the supplier certificate says something higher?

Conditions: PeptideMeter · 97.6%. I think I have a problem. I am not yet sure whether it is a real problem or a measurement artefact. I want to know whether this is…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

466 questions
batch-testing
batch-testing

Testing at the batch or lot level: sampling plans, how many vials from a lot need testing to say anything about the lot, and the difference…

865 questions
asked by j_wierzbicki 45k · 22 months ago
27 votes 5 answers15k views
Is 97.6% a realistic purity ceiling for dulaglutide given its chain length?

Details up front: 97.6% · dulaglutide. This should be a straightforward calculation and I keep getting two different answers. The numbers are arbitrary; the method is…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

466 questions
peptide-mapping
peptide-mapping

Enzymatic digestion followed by LC-MS/MS to confirm sequence rather than just mass. The method that catches a scrambled sequence or a D-amino-acid…

83 questions
asked by anja_hellstrom 13k · 17 months ago
27 votes5 answers13k views
What counter-ion should I expect on a QST tirzepatide lot?

The case in front of me: QST · tirzepatide. The figures are clear enough; the question is what they mean and what they do not. I can supply the numbers if the…

acetate-content
acetate-content

Counter-ion content, most often acetate or trifluoroacetate, and why it matters: the counter-ion and residual water are part of the gross mass you…

87 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
content-assay
content-assay

Quantified content: how many milligrams of peptide are actually in the vial, measured against a calibrated reference standard. A separate test…

438 questions
asked by nkem_obiora 46k · 10 months ago
27 votes0 answers13k views
How do I read an impurity table on a liraglutide certificate against the 99.1% headline?

The particulars: liraglutide · 99.1%. I would rather understand the derivation than memorise the outcome. Two people I asked gave two answers that differ by a factor…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
coa
coa

Certificates of analysis: what fields a useful one carries, how to tell a real analytical report from a marketing document, batch and lot…

749 questions
hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

466 questions
asked by vial_five 15k · 13 months ago
27 votes 5 answers12k views
What does a sterility test add for retatrutide that a purity figure does not?

What I have: a sterility test · retatrutide. I want to know what the trade-off actually is rather than which option is fashionable. I would rather have a defensible…

content-assay
content-assay

Quantified content: how many milligrams of peptide are actually in the vial, measured against a calibrated reference standard. A separate test…

438 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
coa
coa

Certificates of analysis: what fields a useful one carries, how to tell a real analytical report from a marketing document, batch and lot…

749 questions
asked by fibre_or_fragment 12k · 6 months ago
27 votes 5 answers11k views
Does racemisation of orforglipron at minus 80 °C show up as a loss of content or of purity?

Numbers first: racemisation · orforglipron · minus 80 °C. I can predict the outcome but I cannot explain it, which means I will get the next case wrong. I would like…

peptide-stability
peptide-stability

The chemistry of peptide degradation: deamidation, oxidation, hydrolysis, aggregation and fibrillation, and how temperature, pH, ionic strength,…

832 questions
content-assay
content-assay

Quantified content: how many milligrams of peptide are actually in the vial, measured against a calibrated reference standard. A separate test…

438 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
asked by lukas_sedlacek 17k · 15 months ago
27 votes3 answers7.8k views
Should I care about the injection volume on a chromatogram?

I have the report as a PDF with the chromatogram on page two, so I can quote specifics. I would like the mechanism, because I want to be able to reason about the…

hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

466 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

179 questions
asked by tobias_reint 19k · 6 months ago
26 votes5 answers45k views
What does peptide mapping add for semaglutide that a purity figure does not?

The specifics, since they change the answer: peptide mapping · semaglutide. The comparison I want does not seem to exist anywhere in a form I can evaluate. I have…

content-assay
content-assay

Quantified content: how many milligrams of peptide are actually in the vial, measured against a calibrated reference standard. A separate test…

438 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
coa
coa

Certificates of analysis: what fields a useful one carries, how to tell a real analytical report from a marketing document, batch and lot…

749 questions
asked by siobhan_deasy 16k · 21 months ago
26 votes5 answers44k views
What counter-ion should I expect on a QYB semaglutide lot?

The specifics, since they change the answer: QYB · semaglutide. I have the document in front of me and I can read the numbers. What I cannot do is interpret them. I…

acetate-content
acetate-content

Counter-ion content, most often acetate or trifluoroacetate, and why it matters: the counter-ion and residual water are part of the gross mass you…

87 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
content-assay
content-assay

Quantified content: how many milligrams of peptide are actually in the vial, measured against a calibrated reference standard. A separate test…

438 questions
asked by dermot_kiely 14k · 21 months ago
26 votes 5 answers44k views
Why does the same method give a different retention time on a new column?

I have both a purity figure and a content figure, which is why the discrepancy is visible. I can predict the outcome but I cannot explain it, which means I will get…

hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

466 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

179 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
asked by bac_or_bust 37k · 2.2 years ago
26 votes5 answers36k views
Does aspartimide formation of liraglutide at minus 80 °C show up as a loss of content or of purity?

Conditions: aspartimide formation · liraglutide · minus 80 °C. This is one of those things that everyone repeats and nobody derives. This matters practically, not…

peptide-stability
peptide-stability

The chemistry of peptide degradation: deamidation, oxidation, hydrolysis, aggregation and fibrillation, and how temperature, pH, ionic strength,…

832 questions
content-assay
content-assay

Quantified content: how many milligrams of peptide are actually in the vial, measured against a calibrated reference standard. A separate test…

438 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
asked by forty_two_c 43k · 18 months ago
26 votes0 answers32k views
What does 99.1% purity on a wide-pore C18 column actually tell me about a mazdutide vial?

The specifics, since they change the answer: 99.1% · a wide-pore C18 column · mazdutide. I have the document in front of me and I can read the numbers. What I cannot…

hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

466 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
coa
coa

Certificates of analysis: what fields a useful one carries, how to tell a real analytical report from a marketing document, batch and lot…

749 questions
asked by ahmed_zerouali 19k · 2.2 years ago
26 votes 5 answers32k views
Is 97.9% a realistic purity ceiling for ecnoglutide given its chain length?

For reference: 97.9% · ecnoglutide. I would like the arithmetic checked rather than the conclusion asserted. I have deliberately not used an online calculator because…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

466 questions
peptide-mapping
peptide-mapping

Enzymatic digestion followed by LC-MS/MS to confirm sequence rather than just mass. The method that catches a scrambled sequence or a D-amino-acid…

83 questions
asked by j_wierzbicki 45k · 16 months ago
26 votes5 answers30k views
Why would Janoshik report 95.2% where the supplier certificate says something higher?

Setup, so nobody has to ask: Janoshik · 95.2%. This is not behaving the way I expected and I want to understand the discrepancy before I act on it. I have…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

466 questions
batch-testing
batch-testing

Testing at the batch or lot level: sampling plans, how many vials from a lot need testing to say anything about the lot, and the difference…

865 questions
asked by tobias_reint 19k · 12 months ago