Accepted answer
More usefully, start with the population. The inclusion criteria of the trial determine what its result can be extrapolated to, and the extrapolation people want is usually to a population the trial excluded.
The early fall in estimated glomerular filtration rate on treatment is haemodynamic rather than structural. Reduced intraglomerular pressure lowers the filtration rate acutely and preserves the glomerulus chronically — the same pattern seen with renin-angiotensin blockade and with SGLT2 inhibition. A dip of a few millilitres per minute in the first weeks, followed by a shallower long-term slope, is the desired trajectory, not a warning sign.
Headline results, principal programmes
| Trial | Agent | n | Duration | Primary result |
|---|
| STEP 1 | Semaglutide 2.4 mg | 1,961 | 68 wk | −14.9 % vs −2.4 % weight |
| STEP 2 | Semaglutide 2.4 mg, T2DM | 1,210 | 68 wk | −9.6 % vs −3.4 % weight |
| SURMOUNT-1 | Tirzepatide 5/10/15 mg | 2,539 | 72 wk | −15 / −19 / −21 % weight |
| SURMOUNT-4 | Tirzepatide, withdrawal | 670 | 88 wk | Continued loss vs substantial regain |
| SELECT | Semaglutide 2.4 mg | 17,604 | ~40 mo | MACE HR 0.80 (0.72–0.90) |
| FLOW | Semaglutide 1.0 mg, CKD | 3,533 | ~3.4 yr | Renal composite reduced; stopped early |
| SURMOUNT-OSA | Tirzepatide, OSA | 469 | 52 wk | AHI reduced with and without PAP |
Absolute risk reduction, worked: if the control-arm event rate is 8.0 per cent over the follow-up period and the hazard ratio is 0.80, the treated rate is approximately 6.4 per cent, the absolute risk reduction is 1.6 percentage points, and the number needed to treat is 1 ÷ 0.016 ≈ 63 over that period. A 20 per cent relative reduction and a number needed to treat of 63 are the same finding stated two ways, and only one of them sounds impressive.
FLOW tested a composite renal endpoint — kidney failure, sustained 50 per cent eGFR decline, or renal or cardiovascular death — in type 2 diabetes with chronic kidney disease, and was stopped early for efficacy[1].
One qualification: a trial that demonstrates an endpoint at a given dose has demonstrated it at that dose. Extrapolating the endpoint down the dose ladder is an assumption, not a finding.
If the trend across three draws is flat, the difference between draws one and two was noise. Most of what people react to is noise.