Accepted answer
The underlying point is that read the estimand before the effect size. Almost every apparent contradiction between two published figures from the same trial resolves once you notice that one is a trial-product estimand and the other is a treatment-policy estimand.
Creatinine is a muscle-derived metabolite, so a substantial loss of lean mass lowers serum creatinine and mathematically raises estimated GFR without anything happening to the kidney. If you have lost twenty kilograms, your creatinine-based eGFR is flattering you. Cystatin C is not muscle-dependent and is the measure to use when the two disagree.
Relative to absolute, worked
| Quantity | Value | Derivation |
|---|
| Control-arm event rate | 8.0 % | From the trial table, not the abstract |
| Hazard ratio | 0.80 | Reported |
| Treated event rate | 6.4 % | 8.0 × 0.80 |
| Absolute risk reduction | 1.6 pp | 8.0 − 6.4 |
| Number needed to treat | 63 | 1 ÷ 0.016 |
| Relative risk reduction | 20 % | 1 − 0.80 |
The last two rows describe the same finding. Only one of them is used in headlines.
ApoB and LDL-C disagree because they measure different things: LDL-C is the cholesterol mass carried in the LDL fraction, ApoB is a count of atherogenic particles. Small dense particles carry less cholesterol each, so a person with many small particles has a concordantly higher ApoB than their LDL-C suggests. When they disagree, ApoB is the better risk marker.
SELECT reported a hazard ratio of 0.80 (95% CI 0.72–0.90) for the primary composite major adverse cardiovascular event endpoint with semaglutide 2.4 mg in overweight or obese adults with established cardiovascular disease and without diabetes[1].
Worth being explicit that this is interpretation of published data and not medical advice. Laboratory results belong in a conversation with whoever ordered them.
Read the confidence interval, read the estimand, and compute the absolute effect yourself. It takes two minutes and it changes how the result feels.
edited 4 Apr 2026 by Dr_Malik_Osei — added the method parameters