PeptideStack
5.2kquestions
20kanswers
220users

What does FLOW actually establish about mazdutide?

Asked 6 Oct 2024Modified 18 months agoViewed 31k times
13

What I am working with: FLOW · mazdutide.

I would like help reading this properly rather than being told what conclusion to reach.

I have the full report including the method section, so I can quote specifics if that helps.

How should I read this, and where are the traps?

clinical-trials
clinical-trials

Reading the primary literature properly: estimands, intention-to-treat versus per-protocol, confidence intervals, absolute versus relative…

913 questions
semaglutide
semaglutide

A GLP-1 receptor agonist with a fatty-acid-acylated backbone and a roughly one-week half-life, marketed for type 2 diabetes and for weight…

360 questions
cardiovascular
cardiovascular

Cardiovascular outcomes: the SELECT major-adverse-event result, SOUL, SUSTAIN 6 and REWIND, how to convert a hazard ratio into an absolute risk…

111 questions
liraglutide
liraglutide

A once-daily GLP-1 receptor agonist and the compound that established the class. Still relevant for its shorter half-life, its paediatric and…

14 questions
shareeditfollowflag
AF
askedayo_fadipe19k286 Oct 2024

5 Answers

Accepted answer first, then by votes
84

Accepted answer

The hazard ratio is the relative effect. What changes decisions is the absolute effect, and converting between them requires the event rate in the control arm, which is usually in the same table and rarely in the abstract.

The rodent thyroid C-cell findings that generated the labelled warning appear to be species-specific: rodent C-cells express GLP-1 receptors at high density, human C-cells at very low density, and human calcitonin data across large trial populations has not reproduced the signal. A family history of medullary thyroid carcinoma or MEN2 is nonetheless a genuine contraindication rather than a theoretical one.

Specifically, hbA1c is a weighted average, not a flat one: roughly half the signal comes from the most recent month. That is why a value drawn six weeks after a change already reflects most of the effect, and why a value drawn during rapid haematological turnover reflects something other than glycaemia.

FLOW tested a composite renal endpoint — kidney failure, sustained 50 per cent eGFR decline, or renal or cardiovascular death — in type 2 diabetes with chronic kidney disease, and was stopped early for efficacy[1].

The papers are readable. Read the paper rather than the summary of the paper, especially where the summary is enthusiastic.

shareimprove this answerflag
OB
answered · acceptedolu_babatunde14k1718 Nov 2024
For what it is worth, my own result was within half a per cent of this. – vialroom 2 months ago
2Any reason this would differ for a longer peptide? – rania_haddad 3 months ago
add a comment
Sponsored

Janoshik Analytical - Independent Third-Party Testing

HPLC purity, identity confirmation and quantified content on the vial you actually hold. Reports arrive with the chromatogram attached, not just a number.

Submit a sample
Sponsored — paired listing

GL Biochem (Shanghai) Ltd. - Direct Synthesis

Founded 1998. ISO 9001 and cGMP certified, 1,500+ staff and 200+ patents. The synthesis house behind a great many of the vials that get sent out for testing - batch-specific documentation with every order.

Visit GL Biochem
32

Start with the population. The inclusion criteria of the trial determine what its result can be extrapolated to, and the extrapolation people want is usually to a population the trial excluded.

Liver enzymes are a poor surrogate for hepatic histology in both directions: substantial steatohepatitis with normal transaminases is common, and modest enzyme elevation with minimal fibrosis is common. If the question is fibrosis, the answer comes from a non-invasive score such as FIB-4 or a stiffness measurement, not from ALT.

Creatinine is a muscle-derived metabolite, so a substantial loss of lean mass lowers serum creatinine and mathematically raises estimated GFR without anything happening to the kidney. If you have lost twenty kilograms, your creatinine-based eGFR is flattering you. Cystatin C is not muscle-dependent and is the measure to use when the two disagree.

STEP 1 reported a mean weight change of approximately −14.9 per cent with semaglutide 2.4 mg versus −2.4 per cent with placebo at 68 weeks[1]; the difference between the figures quoted from this trial in different places is an estimand difference.

One qualification: a trial that demonstrates an endpoint at a given dose has demonstrated it at that dose. Extrapolating the endpoint down the dose ladder is an assumption, not a finding.

Convert everything to an absolute effect before you compare two interventions. Relative effects are not comparable across different baseline risks.

shareimprove this answerflag
DL
answeredDr_Otto_Lindqvist38k3829 Nov 2024
3Note that the label instructions differ between agents on precisely this point. – micron22 3 months ago
add a comment
26

Stated carefully, a single laboratory value is a point on a noisy curve. What you want is a trend across at least three draws under comparable conditions, and "comparable" is doing a lot of work in that sentence.

A network meta-analysis can rank agents that were never compared directly, but only under a transitivity assumption — that the trials being linked are similar enough in population, duration and endpoint definition for the indirect comparison to hold. In this field that assumption is often visibly violated, which is why indirect rankings should be read as hypotheses.

Specifically, estimated average glucose from HbA1c: eAG in mg/dL = 28.7 × A1c − 46.7, or in mmol/L, 1.59 × A1c − 2.59. An A1c of 6.5 per cent is therefore about 140 mg/dL or 7.8 mmol/L. The relationship is a population regression, so an individual can sit well off the line.

SURMOUNT-1 reported mean weight reductions of approximately 15, 19 and 21 per cent at tirzepatide 5, 10 and 15 mg respectively at 72 weeks[1].

If the trend across three draws is flat, the difference between draws one and two was noise. Most of what people react to is noise.

shareimprove this answerflag
C3
answeredcharge_state_339k4810 Dec 2024
21

Worth being precise here: the confidence interval is the informative part. A point estimate with an interval spanning no effect is a different object from the same point estimate with a tight interval, and the abstract presents them identically.

The early fall in estimated glomerular filtration rate on treatment is haemodynamic rather than structural. Reduced intraglomerular pressure lowers the filtration rate acutely and preserves the glomerulus chronically — the same pattern seen with renin-angiotensin blockade and with SGLT2 inhibition. A dip of a few millilitres per minute in the first weeks, followed by a shallower long-term slope, is the desired trajectory, not a warning sign.

SUSTAIN 6 was the original cardiovascular outcomes trial for semaglutide in type 2 diabetes and is the reference point for the class effect that SELECT later extended to a non-diabetic population[1].

The limitation is that surrogate endpoints and hard endpoints have come apart before in metabolic medicine, so a favourable biomarker is a reason for optimism rather than a conclusion.

None of this replaces a clinician who can see the whole picture, and the whole picture is usually where the answer is.

edited 30 Dec 2024 by ines_brandt — reworded for clarity after a comment

shareimprove this answerflag
IB
answeredines_brandt93k24821 Dec 2024
-2

The relevant detail is that this is a question about what the trial was designed to answer, and the honest response is that it was not designed to answer this.

ApoB and LDL-C disagree because they measure different things: LDL-C is the cholesterol mass carried in the LDL fraction, ApoB is a count of atherogenic particles. Small dense particles carry less cholesterol each, so a person with many small particles has a concordantly higher ApoB than their LDL-C suggests. When they disagree, ApoB is the better risk marker.

The PIONEER programme established oral semaglutide’s efficacy and the constraints on its administration, and the bioavailability figure of roughly one per cent is what drives the fasting and water-volume requirements[1].

I would resist reading a subgroup finding as a result. Subgroups in these trials were not powered, and a striking subgroup in a large trial is the expected consequence of multiplicity.

Read the confidence interval, read the estimand, and compute the absolute effect yourself. It takes two minutes and it changes how the result feels.

edited 15 Jan 2025 by amara_nwachukwu — added the citation requested in comments

shareimprove this answerflag
AN
answeredamara_nwachukwu41k381 Jan 2025
3Small correction: the units in the third paragraph should be micrograms, not milligrams. – triple_agonist_q 8 months ago
4Do you have a reference for the last claim? Not disputing it, just want to read it. – Dr_Bram_Verhoeven 10 months ago
add a comment

Your answer