Accepted answer
Freeze-thaw damage happens at the moving ice front, not at the storage temperature. Once the sample is frozen solid and cold, very little is happening. The damage is done during freezing and thawing, which is why the number of cycles matters and the duration of the hold mostly does not.
Light matters for specific residues rather than in general. Tryptophan and to a lesser extent tyrosine and methionine are photo-labile; a sequence without them is largely indifferent to ambient light over the timescales in question. Amber glass is cheap insurance rather than a requirement.
Reported and extrapolated stability by condition
| State | Condition | Usable window | Basis |
|---|
| Lyophilised solid | −20 °C, sealed, dry | 24–36 months | Supplier guidance |
| Lyophilised solid | 2–8 °C, sealed | 12–24 months | Supplier guidance |
| Lyophilised solid | 25 °C, sealed | 4–8 weeks | Extrapolated (Arrhenius) |
| Lyophilised solid | 40 °C, sealed | 1–2 weeks | Extrapolated |
| Solution, preserved | 2–8 °C | 28 days | USP microbiological convention |
| Solution, preserved | 25 °C | 3–7 days | Extrapolated |
| Solution, unpreserved | 2–8 °C | 24 hours | USP microbiological convention |
Windows for the solid state are chemical; windows for solution are microbiological and usually shorter than the chemical limit.
It helps to be literal here: the 28-day figure for a reconstituted preserved vial is microbiological, not chemical. Chemically, a well-behaved peptide at 5 mg/mL at 4 °C will typically lose well under a per cent of content per month. The reason to respect the date is bioburden, and bioburden is a function of how many times you have opened it, not of the calendar.
The licensed semaglutide and tirzepatide presentations carry in-use periods of several weeks at room temperature in their labelling, which is the closest thing to real stability data in this space — and it applies to a buffered, surfactant-containing, preservative-containing formulation, not to a reconstituted research vial.
One qualification: none of this addresses sterility. A vial can be chemically pristine and microbiologically compromised, and a chromatogram will not tell you which.
The single highest-value change most people can make is buying a cheap logging thermometer, because it converts an assumption about their storage into a record.
edited 12 Mar 2025 by Dr_Yusuf_Adeyemi — corrected a unit error in the worked example