Content assay and purity are orthogonal measurements answering orthogonal questions, and the confusion between them is one of the most expensive misreadings in this space.
The single most common reason for disagreement between a supplier content figure and an independent assay is using different standards.
Running multiple independent aliquots of the same sample should give results that agree to within the method precision, which is usually one to three per cent.
Pharmacopoeial guidance on quantitative methods specifies validation steps for linearity, range, accuracy and precision that most research-grade work does not claim to meet.
The limitation is that a quantitative method is only as good as the standard it uses, and a cheap standard is a false economy.
If a supplier gives you content without the standard's purity, ask them to provide it.
8Useful. I have added the accept threshold suggestion to my own notes. – RP_C18 42 days ago add a comment