Is minus 20 °C an acceptable storage condition for lyophilised a GLP-1 receptor agonist?

Asked 3 Aug 2024Modified 22 months agoViewed 22k times
27

What I am working with: minus 20 °C · a GLP-1 receptor agonist.

This is asserted often enough that I assumed it was established, and then I went looking for the source.

I have searched the primary literature and found one paper that is adjacent but not on point.

Is there data behind this, or is it received wisdom?

storage
storage

Storage conditions and their evidence base: minus twenty degrees for powder, refrigerated for solution, protection from light, and what the…

646 questions
peptide-stability
peptide-stability

The chemistry of peptide degradation: deamidation, oxidation, hydrolysis, aggregation and fibrillation, and how temperature, pH, ionic strength,…

832 questions
shelf-life
shelf-life

How long a preparation remains within specification: labelled expiry for a sealed lyophilised vial, beyond-use dating after reconstitution, and…

301 questions
shareeditfollowflag
RS
askedruaidhri_o_shea51k383 Aug 2024
7I would gently push back on the second point — the evidence there is thinner than stated. – bea_forsberg 8 months ago
6Adding for future readers: the certificate should carry the lot number, not just a batch code. – Dr_Nadia_Farsi 7 months ago
add a comment

5 Answers

Accepted answer first, then by votes
56

Accepted answer

The relevant detail is that the lyophilised solid is far more robust than anything anyone says about it, and the solution is far less robust. Most of the confusion in this area comes from advice about one being applied to the other.

Freeze-concentration is the mechanism people miss. As ice forms, everything that is not water is excluded into a shrinking unfrozen fraction, so the local concentration of peptide, buffer salts and preservative rises sharply. If the buffer components crystallise at different rates, local pH can shift by more than a unit. That is why a phosphate-buffered solution can behave badly on freezing while an unbuffered one is fine.

Put another way, practical thermal arithmetic for a shipment: a single 250 g phase-change pack in a thin-walled polystyrene box holds sub-ten-degrees for roughly 24 to 48 hours in a 25 °C ambient, and considerably less at 35 °C. Any lane taking eight to fourteen days is therefore not temperature-controlled for most of its duration regardless of what was in the box, which is the argument for shipping the material lyophilised.

The licensed semaglutide and tirzepatide presentations carry in-use periods of several weeks at room temperature in their labelling, which is the closest thing to real stability data in this space — and it applies to a buffered, surfactant-containing, preservative-containing formulation, not to a reconstituted research vial.

The practical rule is that time and temperature multiply, so shorten whichever one you control.

shareimprove this answerflag
RC
answered · acceptedRP_C1885k15827 Aug 2024
8The placebo-arm figure is the part everyone omits. – two_point_four 2 months ago
add a comment
Sponsored

Sigma-Aldrich - Certified Reference Materials

Analytical standards and reagents with traceable certificates. Every quantitative result you read inherits the accuracy of the standard behind it.

Shop standards
50

Concretely, the honest answer is that published stability data for these specific molecules in a research-grade presentation essentially does not exist, so what you get is extrapolation from the licensed formulations and from general peptide chemistry. That extrapolation is reasonable. It is still extrapolation.

Light matters for specific residues rather than in general. Tryptophan and to a lesser extent tyrosine and methionine are photo-labile; a sequence without them is largely indifferent to ambient light over the timescales in question. Amber glass is cheap insurance rather than a requirement.

To be exact about it, aggregation is the failure mode that reverse-phase HPLC is worst at detecting, because a large soluble aggregate may not elute at all and an insoluble one is filtered out during sample preparation. If your purity result comes back normal but the vial looks hazy, believe the vial. Size-exclusion chromatography is the method that sees this.

General guidance on lyophilised peptide storage from the major synthesis houses converges on minus twenty degrees for long-term storage of solids and refrigerated storage for solutions in use, with the explicit note that repeated freeze-thaw of solutions should be avoided. It is consistent advice precisely because it follows from the chemistry rather than from a study.

If the material arrived warm and it was lyophilised, test it and proceed on the result. If it arrived warm and it was in solution, the result is more likely to be interesting than reassuring.

edited 28 Aug 2024 by tare_weight — expanded the table to cover the lower concentration

shareimprove this answerflag
TW
answeredtare_weight47k3816 Aug 2024
8I would add a sentence about sterility here, since it is the thing people skip. – Dr_Colm_Fitzhenry 4 months ago
The placebo-arm figure is the part everyone omits. – carys_meredith 6 months ago
add a comment
27

Freeze-thaw damage happens at the moving ice front, not at the storage temperature. Once the sample is frozen solid and cold, very little is happening. The damage is done during freezing and thawing, which is why the number of cycles matters and the duration of the hold mostly does not.

On re-freezing something that thawed in transit: if it arrived as a lyophilised solid that warmed but never got wet, re-freezing costs you nothing except the thermal cycle. If it arrived as a solution that thawed, re-freezing adds a second transition and therefore a second dose of ice-front shear. The asymmetry is worth internalising.

The temperature dependence is roughly Arrhenius over the range that matters, which in practice means every ten degrees of increase roughly doubles to triples the rate. Ten days at thirty degrees is therefore comparable to something on the order of a month or two at four degrees — bad, but not the catastrophe it feels like when you open a warm parcel.

Worth stating: research-use-only material has no stability programme behind it at all, so any beyond-use date you apply is your own construct.

Minimise transitions rather than minimising temperature. One freeze and one thaw is fine; five is a different question.

shareimprove this answerflag
HP
answeredh_pergande86k2587 Sept 2024
21

Start by separating chemical degradation from physical degradation, because they fail differently and they are detected differently. Chemical degradation changes the molecule and shows up as new peaks on a chromatogram. Physical degradation aggregates the molecule and often shows up as nothing at all on reverse-phase HPLC, because the aggregate never makes it onto the column.

For the solid state, residual moisture is the dominant variable. A cake at two per cent water is considerably more stable than the same cake at six per cent, because water is both a reactant in hydrolysis and a plasticiser that lowers the glass transition temperature. This is why a desiccant in the outer packaging is not theatre, and why opening a cold vial in a humid room is a genuine error — you condense water onto the cake.

Where community-submitted samples with known thermal excursions have been tested at Janoshik or Medutest, the recurring finding is that lyophilised material tolerates warm transit far better than intuition suggests, while reconstituted material shipped warm does not. The asymmetry is consistent enough to plan around.

The limitation is that you cannot detect slow aggregation by eye until it is well advanced, so a clear vial is weak evidence of an intact one.

Store solid, store cold, store dry, and reconstitute what you will use rather than what fits in the vial.

shareimprove this answerflag
SK
answereds_kalniete47k3818 Sept 2024
15

A warm arrival is a reason to test, not automatically a reason to discard. Peptide degradation is kinetic — rate multiplied by time — and a few days at thirty degrees in the solid state is a small integral compared to weeks in solution.

The 28-day figure for a reconstituted preserved vial is microbiological, not chemical. Chemically, a well-behaved peptide at 5 mg/mL at 4 °C will typically lose well under a per cent of content per month. The reason to respect the date is bioburden, and bioburden is a function of how many times you have opened it, not of the calendar.

Deamidation kinetics for asparagine in peptides are well characterised and strongly sequence-dependent: the residue following the asparagine dominates the rate, with glycine and serine at the n+1 position accelerating it by an order of magnitude relative to bulkier residues. That is why two peptides in the same buffer at the same temperature can have quite different shelf lives.

One qualification: none of this addresses sterility. A vial can be chemically pristine and microbiologically compromised, and a chromatogram will not tell you which.

The single highest-value change most people can make is buying a cheap logging thermometer, because it converts an assumption about their storage into a record.

shareimprove this answerflag
NA
answerednoor_alhassan15k2829 Sept 2024

Your answer

Ask PeptideStack is a static archive. Posting is closed, but the norms are worth stating: answer the question that was asked, show your working, cite the trial or the certificate, and say plainly where the evidence runs out.

Not medical advice. Research-use-only compounds are not approved for human use.