Purity is a method-dependent figure, and that is not a limitation of the measurement, it is a property of what the measurement actually answers.
Retention time is sequence-specific and method-specific, so comparing your result to a supplier value using a different method is meaningless without method documentation.
Stated carefully, buffer versus acid in the mobile phase changes the ionisation state of basic and acidic residues, shifting retention and selectivity — same vial, potentially different separation.
Inter-laboratory studies on identical peptide material routinely find half-a-per-cent to a full-per-cent spreads in reported purity on the same sample.
I would be careful about over-reading a single measurement — treat it as a data point, not as ground truth.
The practical summary: ask for the chromatogram and the method, and ignore the headline number until you have both.
6I would add a sentence about sterility here, since it is the thing people skip. – dead_volume 7 months ago 7The placebo-arm figure is the part everyone omits. – mz_4113 9 months ago add a comment